Observe the following warnings when performing a hot-plug replacement procedure.
WARNING:
injury and ensure a properly functioning system when performing hot-plug operations.
WARNING:
Remove watches, rings, or other metal objects.
Use tools with insulated handles.
Do not place tools or metal parts on top of batteries.

Removing a memory board blank

To remove the memory board blank, squeeze the levers and pull the blank out of the server.
Removing and installing a memory board while the server is
running
Memory boards can be installed while the server is running in the following scenarios:
Memory boards can be hot-added if the server is configured for Advanced ECC and hot-add is
enabled in RBSU.
Memory boards can be hot-replaced if the server is configured for hot-plug mirrored memory or hot-
plug RAID memory.
IMPORTANT:
in a server that is not configured for Advanced ECC, hot-plug mirrored memory, or hot-plug
RAID memory.
Unlock the locking switch, and open the release latch.
1.
CAUTION:
attempt to remove any memory board with the Removable LED off.
Always comply with all electrostatic and thermal guidelines to prevent bodily
To prevent personal injury from hazardous energy:
Be sure to power down the server when performing board removal procedures
Only memory boards with a green Removable LED can be removed. Do not
Memory options 73