Installation Instruction for Koker with thermostat
Top pointer is to be set at warmth desired in home. Bottom pointer is the present
temperature in room. When room temperature (bottom pointer) falls below
desired room temperature, (top pointer), this will send a signal to the Relay
control to activate gear motor to push fresh coal onto grate
1.
HIGH LIMIT POINTER-is a safety switch that stops gear motor from
pushing coal onto grate at 200 degrees (If stove gets too hot, this switch will
turn off gear motor).
2.
CENTER POINTER-turns convection blower on when internal air
temperature reaches this setting (normally set around 160 degrees, but is
adjustable).
3.
LOW POINTER-turns convection blower off when internal air temperature
falls to this setting (normally set around 120 degrees, but is adjustable).
4.
Whatever number on silver dial is directly above this point is temperature of
internal air.
5.
WHITE BUTTON-pull out for automatic operation of convection blower.
Push in for constant running of convection blower.

THERMOSTAT

FAN LIMIT SWITCH