SETUp & TESTINg
INSTAllER SYSTEM SETTINgS TAblE
System setting
23 . Partial lockout type
24. Max setpoint change
in lockout
25 . Integral factor period
(P+I control)
26. Deadband
27. Progressive recovery
28. Low balance point
29 . High balance point
30 . Program format
31. Event configuration
32. Events per day
33. Change air filter
alarm
34. Change water panel
alarm
35 . Humidifier type
36. Service dehumidifier
alarm
37. Service HVAC alarm
38. Constant backlight
39. Backlight intensity
40. Daylight savings
61000729A 8600 Tstat Install.indd 7
(CONTINUED)
Description
Select lockout type (only available
when screen lockout is set to
partial lockout)
Select setpoint limits (only
available when screen lockout is
set to partial lockout)
Short period = more cycles per
hour (comfort) Long period = less
cycles per hour (economical)
Auto changeover mode dead band
Enable or disable Progressive
recovery
Outdoor temperature low balance
point (This option is only displayed
if the outdoor temperature sensor
is enabled)
Outdoor temperature high balance
point (This option is only displayed
if the outdoor temperature sensor
is enabled)
Select weekly program format
Setting for event naming
Number of program events per
day .
The period for displaying the
"Change Air Filter" message
Set number of months until the
first reminder is required . The
following reminders will occur
every 12 months for a flow through
humidifier, and 3/9 months for a
drainless humidifier
Select humidifier type . Flow
through type gives a 12 month
reminder, and drainless gives a
3/9 month reminder.
The period for displaying the
"Service Dehumidifier" message
The period for displaying the
"Service HVAC" message
Enable constant, low intensity,
backlight when 24VAC is present.
Backlight intensity as a
percentage of full on
Enable or disable auto daylight
savings
factory default setting (bold) and setting range
Allow changes to fan Mode, System Mode and Setpoints
Allow changes to Fan Mode and Setpoints only
Allow changes to Setpoints only
±3° f or C (from current setpoint)
±1° to 20° OFF indicates no setpoint changes
2 minutes
1 to 5 minutes or "OFF" for proportional control only
3°f (2°C)
2°F to 9°F (1°C to 5°C)
Disable
Enable
20°f (–6°C)
10°F to 50°F (-12°C to 9°C) or OFF to ignore
65°f (18°C)
40°F to 65°F (3°C to 18°C) or OFF to ignore
7-day (Mon, Tue, wed, Thu, fri, Sat, Sun)
5/1/1 (weekdays, Saturday and Sunday)
5/2 (weekdays and weekends)
non-programmable
Residential
Commercial
Selects 4 events per day
Selects 2 events per day
Off
1, 3, 6, 12 months or "OFF" to disable
Off
1 to 12 months or "OFF" to disable
flow through type humidifier (1 reminder per season)
Drain-less type humidifier (2 reminders per season)
Off
1 to 12 months or "OFF" to disable
Off
1 to 12 months or "OFF" to disable
Disable
Enable
100
0 – 100%
OFF
March (second Sunday in March to the first Sunday
in November)
April (first Sunday in April to the last Sunday in October)
7
10/8/10 10:32:42 AM