Lincoln Electric INVERTEC V350-PRO SVM152-A Service Manual page 25

Lincoln electric welding system user manual
Hide thumbs Also See for INVERTEC V350-PRO SVM152-A:
Table of Contents

Advertisement

C-9
CONNECTION OF THE LN-10 TO THE
V350-
PRO USING THE K1505 CONTROL CABLE.
NOTE: AN LN-10 CAN ONLY BE USED WITH A FAC-
TORY OR "CE" VERSION OF THE V350-PRO.
1. Remove input power to the V350-PRO.
2. Connect the K1505 control cable from the LN-10
to the Invertec 24/42VAC 14 pin amphenol con-
necter on the rear of the V350-PRO.
3. Connect the electrode cable to the output terminal
of polarity required by the electrode. Connect the
work lead to the other terminal.
4. Set the meter polarity switch on the front of the
V350-PRO to coincide with wire feeder polarity
used.
5. Set "CONTROL SELECT" to "REMOTE".
6. Set the "MODE" to the "CV-WIRE" position..
7. Set the "WELD TERMINALS SELECT" to the
"REMOTE" position.
14 PIN
AMPHENOL
(24/42VAC)
AT REAR OF
MACHINE
ACCESSORIES
Figure C.8 LN-10 V350-PRO
+
-
V350-PRO
8. Set the "ARC CONTROL" to the "0" position and
then adjust to suit.
9. Set wire feed speed and voltage at the LN-10.
NOTE: The voltage set point displayed on the
V350-PRO should be ignored when operating in
the remote control mode with the LN-10.
10. See the LN-10 manual for details on accessing
the control DIP switch.
11. The control DIP switch inside the LN-10 should be
set as shown below for operation with the V350-
Pro.
Power Sources
ON
1
2
3
4
S1
TO LN-10
K1505
TO WORK
ELECTRODE CABLE
TO LN-10
C-9
S1
5
6
8
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents