Comfort Glow CRL2718PA Owner's Operation And Installation Manual page 20

Table of Contents

Advertisement

OPERATING HEATER
Continued
5. Slightly depress and turn control knob
counterclockwise
position. Press in control knob for five (5)
seconds (see Figure 30).
Note: You may be running this heater for
the first time after hooking up to gas sup-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
6. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure.
7. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
Note: If pilot goes out, repeat steps 3
through 7. If control knob does not pop out
when released, contact a qualified service
person or gas supplier for repairs.
8. Slightly depress and turn control knob
counterclockwise
ing level. The burner(s) should light. Set
control knob to any heat level between HI
and LO.
9. To leave pilot lit and shut off burners only,
turn control knob clockwise
HI position then press in and turn clockwise
to PILOT position.
WARNING: Do not operate
heater between PILOT and HI
positions.
Ignitor Button
Figure 30 - Control Knob and Ignitor
Button Location
0
to the PILOT
to desired heat-
Control Knob
www.desatech.com
Ignitor
Electrode
Thermocouple
VARIABLE CONTROL
The variable control valve can be set to any
heat setting and flame height desired, by simply
turning the control knob until that setting is
attained. Even the lowest setting provides re-
alistic, dancing yellow flames. Selecting higher
settings produces greater heat output. This
results in increased heating comfort.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
1. Press in and turn control knob clockwise
2. Turn control knob clockwise
pilot position.
3. Press in control knob and turn clockwise
4. Close equipment shutoff valve (see Figure
to the
16, page 15).
1. Follow steps 1 through 5 under Lighting
Instructions, pages 19 and 20.
2. Depress control knob and light pilot with
match.
3. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob. Now follow step 8, under
Lighting Instructions, column 1.
Pilot Burner
Figure 31 - Pilot
OpERATION
TO TURN OFF GAS
TO AppLIANCE
to the HI position.
to the OFF position.
MANUAL LIGHTING
pROCEDURE
to the
113097-01H

Advertisement

Table of Contents
loading

Table of Contents