Step
Test
4
Switch PC Board
resistance test.
No dynamic test
is possible.
Remove leads
401/403, 1/8, 9,
12, 4/5 and
402/404.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con-
tact your local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
Check
Terminals on Switch
>1K ohms
PC Board:
1/8 (pos) to
12 (neg)
<100 ohms
1/8 (neg) to
<100 ohms
12 (pos)
>1K ohms
9 (pos) to
>1K ohms
4/5 (neg)
<100 ohms
9 (neg) to
<100 ohms
4/5 (pos)
>1K ohms
1/8 (pos) to
<100 ohms
9 (neg)
>1K ohms
1/8 (neg) to
>1K ohms
9 (pos)
<100 ohms
12 (pos) to
<100 ohms
4/5 (neg)
>1K ohms
12 (neg) to
>1K ohms
4/5 (pos)
<100 ohms
12 (pos) to
>1K ohms
401/403 (neg)
<100 ohms
12 (neg) to
<100 ohms
401/403 (pos)
>1K ohms
9 (pos) to
<100 ohms
402/404 (neg)
>1K ohms
9 (neg) to
>1K ohms
402/404 (pos)
<100 ohms
CAUTION
Test
Conclusion
Result
OK
Short
OK
Open
OK
Short
OK
Open
OK
Open
OK
Short
OK
Open
OK
Short
OK
Short
OK
Open
OK
Open
OK
Short
17
Next
Test
Step
Repair Action
cont
5
Replace Switch PC Board
cont
5
Replace Switch PC Board
cont
5
Replace Switch PC Board
cont
5
Replace Switch PC Board
cont
5
Replace Switch PC Board
cont
5
Replace Switch PC Board
cont
5
Replace Switch PC Board
cont
5
Replace Switch PC Board
cont
5
Replace Switch PC Board
cont
5
Replace Switch PC Board
cont
5
Replace Switch PC Board
cont
5
Replace Switch PC Board