Kenwood NX-300 Service Manual page 50

Uhf digital transceiver
Hide thumbs Also See for NX-300:
Table of Contents

Advertisement

NX-300
Item
Panel tuning mode
QT
1) Adj item: [Aw QT]
Deviation
Adjust: [✳✳✳✳]
adjust *4
PTT: ON
Press [ ] key to store
[Wide]
the adjustment value.
7. DQT
1) Adj item: [An DQT]
Deviation
Adjust: [✳✳✳✳]
adjust *4
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [ ] key to store
the adjustment value.
[Wide]
1) Adj item: [Aw DQT]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
8. LTR
1) Adj item: [An LTR]
Deviation
Adjust: [✳✳✳✳]
adjust *4
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [ ] key to store
the adjustment value.
[Wide]
1) Adj item: [Aw LTR]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
9. DTMF
1) Adj item: [An DTMF]
Deviation
Adjust: [✳✳✳✳]
adjust *4
Deviation meter
LPF: 15kHz
[Narrow]
HPF: OFF
PTT: ON
Press [ ] key to store
the adjustment value.
[Wide]
1) Adj item: [Aw DTMF]
Adjust: [✳✳✳✳]
PTT: ON
Press [ ] key to store
the adjustment value.
50
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [QT Devia-
Deviation
tion (Analog Wide)]
meter
PTT: Press
Oscilloscope
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [DQT Devia-
tion (Analog Narrow)]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [DQT De-
viation (Analog Wide)]
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [LTR Devia-
tion (Analog Narrow)]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [LTR Devia-
tion (Analog Wide)]
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [DTMF De-
viation (Analog Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
1) Adj item: [DTMF De-
viation (Analog Wide)]
PTT: Press
[Transmit] button.
Press [Apply]
button to store the
adjustment value.
Measurement
Test-
Unit Terminal Unit
Panel
ANT
Panel
Adjustment
Specifi cations /
Parts
Method
[Panel
Write the value as
0.75kHz±0.05kHz
tuning
followings.
mode]
513 (Reference
[
],
value)
[
]
[PC test
mode]
Write the value as
0.35kHz±0.05kHz
[ ],[ ]
followings.
415 (Reference
value)
0.75kHz±0.05kHz
Write the value as
0.75kHz±0.05kHz
followings.
465 (Reference
value)
1.00kHz±0.05kHz
Write the value as
1.25kHz±0.05kHz
followings.
540 (Reference
value)
2.50kHz±0.05kHz
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents