to change the SET TEMP (45-90 deg. F,
7-32 deg. C); the new set temperature
will automatically be accepted after 2
seconds. The factory default SET TEMP
is 68 deg. F.
SWING Temperature: This model does
not allow for SWING temperature adjust-
ment. This model utilizes thermostatic
flame modulation that will modulation
the main flame based on the difference
between room temperature and set tem-
perature (see example below).
Important - factory SWING TEMPERA-
TURE setting is 2 degrees. The thermo-
static flame modulation feature will not
allow this SWING to be changed.
EXAMPLE:
Set Temperature
Set Temperature (72)
Pilot Method: Continuous/Standing Pilot
only (Intermittent Pilot Ignition (IPI)/
Spark-to-Pilot not allowed).
Pilot flame will remain ON when Main
Flame Cycles ON and OFF.
Manual Flame Adjustment while in
THERMOSTAT mode: If Flame-A is
manually adjusted while in thermostat
mode, it will override the automatic
flame setting until the flame cycles off,
then back ON thermostatically; when
the flame cycles ON again, automatic
flame adjustment will resume. Automatic
flame adjustment will also resume if the
operational mode is cycled out of, then
back into THERMOSTAT mode or if the
SET temperature is changed.
THERMOSTAT OFF LCD Displays:
MODE Zone: THERMO and OFF is
displayed
ROOM TEMP Zone: Measured tempera-
ture is displayed
SET TEMP Zone: SET TEMP is dis-
played
TIME/PROG Zone: Current day indicator
and current time is displayed
FLAME Zone: Blank
THERMOSTAT ON LCD Displays:
126867-01A
OPERATION
Room Temp.
Flame Level
74F
OFF
73F
Level 1
72F
Level 2
71F (or less)
Level 3
www.SuperiorFireplaces.US.com
Continued
• MODE Zone: THERMO and ON are
displayed
• ROOM TEMP Zone: Measured tempera-
ture is displayed
• SET TEMP Zone: SET TEMP is dis-
played
• TIME/PROG Zone: Current day indicator
and current time is displayed
• FLAME Zone: A Flame Icon and flame
setting level number is displayed
Thermostat Disable Feature
The Thermostat Mode (described above)
may be disabled for applications where a
thermostat is not allowed or undesirable.
When Thermostat Mode is Disabled:
• The Modes of operation will cycle be-
tween MANUAL ON and MANUAL OFF
(omitting THERMO).
• Program Operation (described below) is
also disabled.
• The SET TEMP zone will be blank.
• The room temperature will still be mea-
sured & displayed in the ROOM TEMP
Zone.
• The TIME/PROG zone will continue to
display the Clock and Day of week, but
none of the icons associated with Pro-
gram Mode will be displayed.
To disable or re-enable the Thermostat,
the transmitter must be in MANUAL
OFF Mode, then touch and hold the
SET TEMP Zone and the DOWN Button
simultaneously for 10- seconds. The
LCD screen will go blank except either
THERMO and OFF or THERMO and
ON will flash 3-times (0.5-seconds OFF,
0.5-seconds ON) to indicate the change
has been made.
DAY AND TIME DISPLAY
The current day of week and time of
day will be continuously displayed in the
TIME/PROG Zone (except during Setup
operations).
The day of week will be displayed as
one of the following: S, M, T, W, T, F, S
The time of day will be in 12-hour AM,
12-hour PM format. Midnight will be
displayed as 12:00am.
Day/Time Setup:
1. Press and hold the MODE Zone for 5
seconds to enter Day/Time Setup.
25