Installation; Technical Specifications - Lincoln Electric IDEALARC IM10018-A Operator's Manual

Lincoln electric welding consumables user manual
Table of Contents

Advertisement

A-1
TECHNICAL SPECIFICATIONS – IDEALARC® DC-600 VRD
CODES
11613, 11707
230/460/575/60
11598, 11725
Duty Cycle
100% Duty Cycle
60% Duty Cycle
50% Duty Cycle
Output Range
70A/13V-780A/44V (CV)
90A/24V-780A/44V (CC)
INPUT
VOLTAGE /
FREQUENCY
230
460
575
415
HEIGHT
30.75 in
781 mm
1 Also called "inverse time" or "thermal/magnetic" circuit breakers; circuit breakers which have a delay in tripping action that decreases as the magnitude of the current increases.

INSTALLATION

INPUT - THREE PHASE ONLY
Standard
Voltage
100% Duty Cycle
108/54/43
415/50/60
RATED OUTPUT
Maximum Open Circuit Voltage
5V for 60 HZ models
5V for 50/60 HZ models
RECOMMENDED INPUT WIRE AND FUSE SIzES
HERTz
INPUT AMPERE
RATING ON
NAMEPLATE
60
108
60
54
60
43
50/60
61
PHYSICAL DIMENSIONS
WIDTH
22.25 in
567 mm
IDEALARC® DC-600 VRD
Input Current at Rated Output
60% Duty Cycle
122/61/49
62
68
Amps
600
680
750
OUTPUT
TYPE 75°C
COPPER WIRE
IN CONDUIT
AWG(IEC-MM
) SIzES
2
30°C (86°F) Ambient
2 (34)
6 (14)
8 (8.4)
6 (14)
DEPTH
39.0 in
988 mm
50% Duty Cycle
134/67/54
73
Volts at Rated Amperes
44
44
44
Auxiliary Power
See the OPERATION section
for Auxiliary Power
information by model
TYPE 75°C
TYPE 75°C
GROUND WIRE
(SUPER LAG)
IN CONDUIT
OR bREAKER
AWG(IEC-MM
) SIzES
SIzE (AMPS)
2
6 (14)
175 Amp
8 (8.4)
90 Amp
8 (8.4)
70 Amp
8 (8.4)
100 Amp
WEIGHT
525 lbs.
238 kg.
A-1
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Idealarc dc-600 vrd11598116131170711725

Table of Contents