E-6
Observe all Safety Guidelines detailed throughout this manual
PRObLEMS
(SYMPTOMS)
Machine has maximum weld out-
put and no control.
VRD passes self test and green
light is on, but machine will not
Weld.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUbLESHOOTING
POSSIbLE
CAUSE
OUTPUT PRObLEMS
1. LOCAL/REMOTE Switch (S3)
in wrong position.
2. LOCAL/REMOTE Switch (S3)
is faulty, or an open lead going
to the LOCAL/REMOTE Switch
(S3).
1. Too much cable inductance.
• Uncoil output cables, shorten
cable length, or wrap work and
electrode cables together.
2. Too much cable.
• Maximum cable length (work
and electrode) is approximately
300 feet.
3. Buildup on stick electrode.
Clean or replace electrode.
4. Possible shorted bridge rectifier,
if pilot light is off.
5. Fault detected after self test.
Cycle power to reset machine.
CAUTION
IDEALARC® DC-600 VRD
RECOMMENDED
COURSE OF ACTION
If all recommended possible areas
of possible cause have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.
E-6