Function
Pin
Notes
1
0 V DC (-)
2
DC output
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3–
Configurable
Digital input – Connect to pin 1 to activate,
4
(Input or
or leave floating (unconnected) to deactivate.
Output)
Digital output – Connected to pin 1 when
activated, floating (unconnected) when
deactivated. If used with an inductive load,
e.g. a relay, a diode must be connected in
parallel with the load, for protection against
voltage transients.
12 V max 50 mA
3.
I/O configured as input
4.
I/O configured as output
AXIS P1365-E Network Camera
1
2
3
4
17
Specifications
0 V DC
12 V D C
Max load = 50 mA
0 to max 30 V DC
0 to max 30 V DC, open
drain, 100 mA