tet ClocuDay
Scheduk
Fan
Svstem
Auto
Auto
Press until screen
displays "Auto"
Note: The Auto system setting
may not appear, depending on
how your thermostat was installed.
Auto Changeover is a feature used in cli-
mates where both air conditioning and heat-
ing are used on the same day. When the sys-
tem is set to Auto, the thermostat automati-
cally selects heating or cooling depending on
the indoor temperature.
Heat and cool settings must be at least 3
degrees apart. The thermostat will automati-
cally adjust settings to maintain this
3-degree separation (called "deadband").
The 3-degree separation between heating
and cooling set temperatures is fixed, and
cannot be changed.
14
FocusPRO'" TH600O Series
@
lnside
-15
Cool
Setting
15"
This feature helps prevent damage to the
compressor in your air conditioning or heat
pump system.
Damage can occur if the compressor is
restarted too soon after shutdown. This fea-
ture forces the compressor to wait for a few
minutes before restarting.
During the wait time, the display will flash
the message Cool On (or Heat On if you have
a heat pump).When the safe wait time has
elapsed, the message stops flashing and the
compressor turns on.