Download Print this page

Honeywell FocusPro TH6000 series Operating Manual page 11

Hide thumbs Also See for FocusPro TH6000 series:

Advertisement

Operating Manual
lf you have difficulty with your thermostat, please try the following suggestions.
Most problems can be corrected quickly and easily.
Display is blank
r
Check circuit breaker and reset if necessary.
.
Make sure power switch at heating & cooling system is on.
.
Make sure furnace door is closed securely.
.
lf thermostat is battery powered, make sure fresh AA alkaline
batteries are correctly installed (see page 17).
Temperature
Make sure heating and cooling temperatures are set to acceptable ranges:
settings do not
.
Heat:40" to 90"F (4.S" to 32.C).
change
.
coot: 50" to 99"F (10" to 37.C).
To restore
Follow these steps to restore Energy Star default seftings (see page 'l0):
Energy Star"
1. press SET CLSCVDAy/SCHEDULE.
default settings
2. press SET SCHEDULE.
3. Press 001'lE and I'IEXT at the same time for 4 seconds.
FocusPRO* TH6O0O Series
1 8
Heating or
cooling system
does not respond
"Cool Ontt or
r'l{eat On" is
flashing
a
a
a
a
a
Press SYSTEM button to set system to Heat. Make sure the temperature
is set higher than the Inside temperature.
Press SYSTEM button to set system to Cool, Make sure the temperature
is set lower than the Inside temperature.
Check circuit breaker and reset if necessary.
Make sure power switch at heating & cooling system is on.
Make sure furnace door is closed securely.
Wait 5 minutes for the system to respond.
Compressor protection feature is engaged. Wait 5 minutes for the system
to restart safely, without damage to the compressor (see page 15).
19

Advertisement