Disassembly Procedures
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit and discharge
capacitor through a 10,000 ohm resistor before attempting to service, unless test procedures require power to be
connected. Ensure all ground wires are connected before certifying unit as repaired and/or operational.

Lower Wash Arm

Water is supplied to the Lower Wash Arm via the Pump
Assembly.
Removal
1. Disconnect power to the machine.
2. Remove lower Rack Assembly.
3. Loosen Wash Arm Hub and Pivot.
4. Lift Wash Arm out of Dishwasher.

Air Water Inlet

The Air Water Inlet is located on the left side of the Tub,
and mounted to the exterior of Tub.
©2006 Maytag Services
!
WARNING
Removal
1. Disconnect power to the machine.
2. Remove Cabinet, see "Cabinet" removal procedure.
3. Remove the Air Water Inlet Cover located on the left
inside wall of Tub. Pull cover straight out to remove.
4. Carefully pull back insulation from the left side of the
Tub.
5. Remove rubber hose from channel in Tub, or slip off of
fitting on inlet.
6. Grasp upper portion of the Air/Water Inlet. Pull and
rotate the Air/Water Inlet clockwise to release it from
the Tub.
Replacement
1. Examine the Air Water Inlet Seal for damage.
2. Align Air Water Inlet tabs with notches in Tub, and
rotate counterclockwise into position.
3. Replace Air Water Inlet Cover inside Tub.