The inside dimension of the frame must be the same as
the hole size selected from Figure 13 in order to provide
Angle of Chimney at Ceiling
Size of Chimney
Vertical
8" Flue
SKFS2A
"SK" Series
14Z⁄₂" x 14Z⁄₂"
(368 mm x 368 mm) (368 mm x 648 mm)
8" Flue
"S" Series 3-Wall
17Z⁄₂" x 17Z⁄₂"
(445 mm x 445 mm) (454 mm x 753 mm)
Fig. 13 Ceiling chimney hole sizes necessary for installing
firestop spacer.
the required 1Z⁄₂" (38 mm) of air space between the out-
side diameter of the chimney and the edges of the framed
ceiling hole.
Positioning, Safety Strips,
Securing the Fireplace
Slide fireplace into position.
Lift the fireplace front slightly and slide the metal safety
strips under front bottom edge about 1Z⁄₂" (38 mm), allowing
the remainder to extend in front of firebox. Overlap strips
at least 1/2" (13 mm) to provide a positive joint. (Flat safety
strips are packed with fireplace.) (Fig. 14)
Safety strips are used to ensure that any combustible ma-
terials in front of the fireplace are protected even though
a noncombustible hearth extension is required.
If fireplace is to be elevated above the floor, a "Z" shaped
metal safety strip must be fabricated and used to protect
combustible surfaces in front of the fireplace. This "Z"
shaped safety strip is not provided but must be fabricated
of metal with each horizontal leg at least 1Z⁄₂" (38mm) wide
and equal in length to the metals strips provided with the
fireplace.
Note: Safety strips are not required over noncombustible
floors where all supports at the base of the fireplace are
noncombustible.
Four (4) nailing flanges are supplied with the fireplace
(found on the fireplace hearth). To level the box and se-
cure it firmly in place, remove the nailing flanges from the
hearth and install at the sides of the fireplace as shown
in Figure 15.
7412944
30°
SKFS6A
14Z⁄₂" x 25Z⁄₂"
FS2A
FS6A
17⁷⁄₈" x 29⁵⁄₈"
BR/BC Series Woodburning Fireplaces
Installing Outside Air Kit
An outside air kit is installed in all BR/BC Series Fireplaces.
If desired, or if local codes mandate the use of an air kit,
then an AK-MST is required to complete the installation
(from air kit to the outdoors). If the outside air kit is to be
used, the AK-MST MUST be installed BeFORe the fire-
place is enclosed. Refer to the AK-MST instructions for
field installation.
NOTe: For Canada installations, model CCE-SK Chimney
Collar Enclosure must be used on this fireplace with Model
SK8 double wall chimney systems.
" (13mm)
Min. Overlap
"
(38mm)
Fig. 14 Safety strip installation.
Fig. 15 Fasten fireplace in position.
Metal Safety Strip
(1,2 or 3 pieces)
"Z"
Fire-
Safety
Place
Strip
(not supplied)
Plat-
Hearth Ext.
Form
FP557
WF557
BR
11/10/97
Nail Top
Standoffs
Nail Side-
Nailing
Flanges
FP549
FP549
9/29/97
BR/BC
11