Saeco Intelia Service Manual page 45

Table of Contents

Advertisement

INTELIA
Initial status
Initial status
If you insert a full drip tray the TANK-H20 indicator must change from "N" to
If you insert a full drip tray the TANK-H20 indicator must change from "N" to
"Y".
"Y".
ERROR condition:
If the indication does not change, check the capacitive sensor and relative wir-
ing (JP23).
Insert grounds drawer
Insert grounds drawer
The DREG indicator must change from "N" to "Y"
The DREG indicator must change from "N" to "Y"
ERROR condition:
ERROR condition:
If the indication does not change, check the microswitch on the dreg drawer
If the indication does not change, check the microswitch on the dreg drawer
and relative wiring (JP16).
and relative wiring (JP16).
Press STAND_BY "
Press STAND_BY "
Saeco International Group
Operational check - microswitches and sensors
Operational check - microswitches and sensors
Close the side hatch (the dreg drawer must be inserted)
Close the side hatch (the dreg drawer must be inserted)
The DOOR indicator must change from "N" to "Y"
The DOOR indicator must change from "N" to "Y"
ERROR condition:
ERROR condition:
If the indication does not change, check the Microswitch on the hatch and
If the indication does not change, check the Microswitch on the hatch and
relative wiring (JP14), make sure that the dreg drawer is correctly in position.
relative wiring (JP14), make sure that the dreg drawer is correctly in position.
Insert the brewing unit
Insert the brewing unit
The BU-P indicator must change from "N" to "Y"
The BU-P indicator must change from "N" to "Y"
(this step takes 2-3 sec)
(this step takes 2-3 sec)
ERROR condition:
If the indication does not change, check the brewing unit microswitch and
relative wiring (JP16)
Insert the brewing unit
Insert the brewing unit
The TRAY indicator must change from "N" to "Y"
The TRAY indicator must change from "N" to "Y"
ERROR condition:
If the indication does not change, check the brewing unit microswitch and
relative wiring (JP04)
" to move to the next screen
" to move to the next screen
Operational check - impuls Milk
Operational check - impuls Milk
NOT USED
NOT USED
Rev. 02 / September 2012
05 TROUBLESHOOTING
Page
12
/ 22