Installation; Technical Specifications - Lincoln Electric POWER WAVE IM846-A Operator's Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

A-1

TECHNICAL SPECIFICATIONS -

Product Ordering Input AC
Name Information Voltage
Power
200-220/
Wave
K 2369-1
380-400/
405M
50/60 Hz
* Overall Length Including Handle, 21.6" (549mm) without handle.
Insulation Class 180 (H)
Recommended Fuse Sizes based On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz
Voltage
Phases
200
3
220
3
380
3
400
3
415
3
Voltage
Phases
200
1
220
1
380
1
400
1
415
1
1. Not rated is indicated by 4-x's in the box on the rating plate
2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.
OUTPUT CAbLES, CONNECTIONS AND LIMITATIONS
Select the output cable size based upon the following chart.
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75°C rated:
DUTY CYCLE
CURRENT
100%
275
60%
350

INSTALLATION

POWER WAVE 405M
INPUT AC VOLTAGE & DC OUTPUT
Rated DC Output
Amps/Volts/Duty Cycle
50/60 Hz
350A / 34V / 60%
3 Phase
320A / 33V / 60%
415
1 Phase
275A / 31V /100%
1 Phase
300A / 32V / 100%
3 Phase
POWER WAVE 405M INPUT CURRENT
Output
300Amps@
350Amps@
32Volts(100%)
34Volts(60%)
41
37
23
22
22
275Amps@
320Amps@
31Volts(100%)
33Volts(60%)
----
64
44
40
38
LENGTH UP 61m (200 FT)
POWER WAVE 405M
Output
Range
(continuous)
AMPS
5-425
Line Cord
AWG SIzES
48
6
48
6
28
8
27
8
26
8
Line Cord
----
---
82
4
55
6
50
8
48
8
1/0
1/0
Weight
Dimensions
with Cord
HxWxD
14.7"x12.5"x
27.8"*
86.5lbs
(373x318x
(37.4 kg)
706*)mm
* Includes
handles
Recommended
Size Fuse Size
80A
80A
50A
50A
50A
Size Fuse Size
-----
125A
80A
80A
80A
61-76m (200-250 FT)
1/0
2/0
A-1
Notes
Note 2
Note 2
Notes
Note 1
Note 2
Note 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power wave 405m

Table of Contents