TECHNICAL SPECIFICATIONS - V200T TIG
Standard
Voltage
(1)
230/460/1/50/60
Duty Cycle
20% Duty Cycle
60% Duty Cycle
100% Duty Cycle
Output Current
Range
1 - 200 A
Height
Power
10.04 in.
255 mm
Source
OPERATING TEMPERATURE
-20°C to +40°C
(1) Input voltage must be within ±10% of rated value.
(2) Duty Cycle is based on a 10 min. period.

INSTALLATION

INPUT - SINGLE PHASE ONLY
Input Current at
45/23 A @ 200 A, 33/16 A @ 150 A,
RATED OUTPUT
(2)
Maximum Open
Circuit Voltage
RECOMMENDED INPUT WIRE AND FUSE SIZES
For DC TIG Welding at 200A/20% Duty Cycle
Based on the 1996 U.S. National Electrical Code
Input
Fuse
Input
Voltage /
(Super Lag)
Ampere
phase/
or Breaker
Rating on
Frequency
Size
Nameplate
230/1/50/60
50
460/1/50/60
30
PHYSICAL DIMENSIONS
Width
7.48 in.
190 mm
INVERTEC V200-T
Rated Output
25/13 A @ 120 A
Amps
200
150
120
OUTPUT
80 V
Type 75°C
Type 75°C
Copper Ground
Copper Wire in
Wire in Conduit
Conduit AWG
AWG (IEC)
(IEC) Sizes
10 (5.2 mm 2 )
10 (5.2 mm 2 )
45
12 (4 mm 2 )
12 (4 mm 2 )
23
Depth
17.32 in.
440 mm
STORAGE TEMPERATURE
Code
Number
10463
Volts at Rated Amperes
28
26
25
Type of Output
DC
Sizes
Weight
Approx. 35 lbs.
16 kgs.
-25°C to +55°C
A-1