Welding In Stick Mode - Lincoln Electric INVERTEC V200-T Operator's Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

B-5

WELDING IN STICK MODE

1. Put the electrode holder and cable quick connect
plug into the proper receptacle for the electrode
polarity desired. Turn clockwise until tight. Connect
the work clamp to the other receptacle and the work
piece.
2. Set the Welding Process Switch to "STICK".
3. Set the Local/Remote Switch to "Local".
4. Place the electrode in the electrode holder.
5. Turn the Power Switch to the proper input voltage
setting to turn on the welder.
RECOMMENDED ELECTRODE AMPERAGE RANGES - INVERTEC V200-T
ELECTRODE
Fleetweld 180
Fleetweld 37
Fleetweld 47
Jet-LH MR
Blue Max Stainless
Red Baron Stainless
Mild steel procedures are based on recommended procedures listed in C2.10 8/94 and the maximum rating of the Invertec V200-T
Jet-LH MR procedures are based on Jet-LH 78 MR
Blue Max procedures are based on C6.1 6/95
Red Baron Procedure are based on ES-503 10/93
Electrode Polarity
Electrode Tip Prepration
Electrode Type
Electrode Size (in.)
.010
.020
.040
1/16
3/32
1/8
Tungsten electrodes are classified as follows by the American Welding Society (AWS):
Pure ..................................EWP ........green
+1% Thoria .......................EWTh-1 ...yellow
+2% Thoria .......................EWTh-2 ...red
+2% Ceria.........................EWCe-2...orange
+1.5% Lanthana ...............EWLa-1 ...black
+0.15 to 0.40% Zirconia....EWZr .......brown
Ceriated Tungsten is now widely accepted as a substitute for 2% Thoriated Tungsten in AC and DC applications.
OPERATION
The Invertec V200-T is rated from1 - 200 Amps.
SMAW Process
POLARITY
DC+
DC+
DC-
DC+
DC+
DC+
GTAW Process
DC-
Sharpened
EWTh-1, EWCe-2
EWTh-2, EWLa-1
EWG
Up to 15 A.
Up to 15 A.
Up to 80 A.
Up to 150 A.
Up to MAX. A.
X
INVERTEC V200-T
WARNING
In Stick Mode the output terminal and
electrode will be electrically hot when-
ever the power switch is turned on.
6. Adjust the Current Control to the desired amps.
7. Strike an arc and weld.
NOTE: When the Welding Process Switch is set to
"STICK" the output is always on when the power
switch is on. A remote control has no effect on the
welding current and the gas flow and high frequency
TIG arc starter are disabled.
3/32"
1/8"
40 - 80
55 - 110
70 - 95
100 - 135
75 - 95
100 - 145
85 - 110
110 - 160
40 - 80
75 - 110
40 - 70
60 - 100
B-5
5/32"
105 - 135
145 - Max
135 - Max
130 - Max
95 - 110
90 - 140
Approximate Argon
Gas Flow Rate
C.F.H. (l/min.)
Stainless
Aluminum
Steel
3-8
(2-4) 3-8
(2-4)
5-10
(3-5) 5-10
(3-5)
5-10
(3-5) 5-10
(3-5)
5-10
(3-5) 9-13
(4-6)
13-17
(6-8) 11-15 (5-7)
15-23 (7-11) 11-15 (5-7)
Sept97