A-1
TECHNICAL SPECIFICATIONS – SP-135 PLUS
Standard Voltage/Frequency
115V/60Hz
Duty Cycle
20% Duty Cycle – Rated DC Output
Welding Current Range (Continuous) Maximum Open Circuit Voltage
Rated DC Output: 25 – 135 Amps
Output Mode
Input Voltage
RATED
115V/60Hz
MAXIMUM
115V/60Hz
Height
12.0 in
305 mm

INSTALLATION

INPUT – SINGLE PHASE ONLY
RATED OUTPUT
RECOMMENDED INPUT CABLE AND FUSE SIZES
Fuse or
Breaker Size
20 Amp
25 Amp
PHYSICAL DIMENSIONS
Width
9.75 in
248 mm
SP-135 PLUS
Input Current
20 Amps @ Rated Output
25 Amps @ Maximum Output
15 Amps @ CSA Rated output
Amps
90
OUTPUT
28
Input Amps
Extension Cord
Three Conductor
#14 AWG
20
(2.1 mm
for up to
25 feet (7.6m)
Three Conductor
#12 AWG
25
(3.3 mm
for up to
50 feet (15.2 m)
Depth
16.5 in
419 mm
Volts at Rated Amperes
18
Auxiliary Power
N/A
2
) or Larger
2
) or Larger
Weight
54 Ibs
24.3 kg