Replacement Parts - Lincoln Electric IM536-D Operator's Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

INNERSHIELD (FCAW)
CONVERSION
Several changes are needed to convert the unit for
operation with the Innershield (FCAW) process. The
K549-1 Innershield Kit includes all the necessary
accessories for this conversion and are provided for
this purpose. The following conversions should be
made using the contents of this kit:
1. Change the output polarity to DC(-). See "Work
Cable Installation" section for details.
2. Install proper drive roll for the wire size selected.
See "Changing Drive Roll" in Maintenance section
for details.
3. Install the proper gun liner and tip for the wire size
selected. See "Component Replacement" in
Maintenance section for details.
4. Remove gas nozzle (if installed) and install gasless
nozzle. To remove, simply unscrew.
ACCESSORIES

REPLACEMENT PARTS

Complete Gun and Cable Assembly
L8311-6 (K530-4)
Contact Tip .025" (0.6 mm)
S19726-1
Contact Tip .030" (0.8 mm)
S19726-2
Contact Tip .035" (0.9 mm)
S19726-3
Contact Tip .045" (1.2 mm)
S19726-4
Contact Tip-Tapered .025" (0.6 mm)
S20278-1
Contact Tip-Tapered .030" (0.8 mm)
S20278-2
Contact Tip-Tapered .035" (0.9 mm)
S20278-3
Contact Tip-Tapered .045" (1.2mm)
S20278-4
Liner .023 - .030" (0.6 - 0.8 mm)
M16291-2
Liner .030 - .035" (0.8 - 0.9 mm)
M16291-6
Liner .035/.045" (0.9/1.2 mm)
M16291-1
Gas Diffuser
S19728
Gas Nozzle
M16294
Gas Nozzle-Tip Recessed 3/8" (9.5 mm)
Opening I.D.
M16684
Gas Nozzle-Tip Recessed 1/2" (12.7 mm)
Opening I.D.
M16684-1
Gas Nozzle-Tip Recessed 5/8" (15.9 mm)
Opening I.D.
M16684-2
Spot Welding Nozzle
M17846-1
Gasless Nozzle (Innershield Only)
M16418
C-2
SP-125 PLUS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp-125 plus

Table of Contents