Flue Terminal Positioning; Flue Options; Flue Terminal Guard - Baxi Duo-tec Combi GA Pocket Technical Manual

Table of Contents

Advertisement

Flue options

Flue options
A
1
B
1
C
1
D
2
E
2
F
2
G
2
H
2
I
J
K
K
L
10
X8013 - Technical pocket guide DL v14_post proof.indd 10
Likely flue positions requiring
a flue terminal guard
Terminal Position with Minimum Distance
Directly below an opening, air brick, opening windows, etc
Above an opening, air brick, opening window etc
Horizontally to an opening, air brick, opening window etc
Below gutters, soil pipes or drain pipes
Below eaves
Below balconies or car port roof
From a vertical drain pipe or soil pipe
From an internal or external corner
Above ground, roof or balcony level
From a surface or boundary line facing a terminal
From a terminal facing a terminal (Horizintal flue)
From a terminal facing a terminal (Vertical flue)
From an opening in carport (e.g. door, window) into
the dwelling
N
R
M
I
I
F
L
Technical Helpline: 0844 871 1525
T
J,K
G
(mm)
300
300
300
25 (75)
25 (200)
25 (200)
25 (150)
25 (300)
300
600
1200
600
1200