Field Effect Transistor/Switch Board Test - Lincoln Electric INVERTEC POWER WAVE 450 SVM112-B Service Manual

Lincoln electric power supply user manual
Table of Contents

Advertisement

F-59

FIELD EFFECT TRANSISTOR/SWITCH BOARD TEST

Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or
machine operator and will invalidate your factory warranty. For your safety and to avoid elec-
trical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
DESCRIPTION
The following procedure will determine if the four switch boards and their related circuitry
are functioning properly. This is a resistance test, not a voltage test. The machine does
not have to be powered up to perform the test, which is both safer for the technician and
less likely to result in accidental damage to the switch boards.
MATERIALS NEEDED
Analog Volt/Ohmmeter (Multimeter)
5/16" Nut driver
3/8" Nut driver
Machine Wiring Diagram in the Electrical Diagrams section of this manual
This procedure takes approximately 60 minutes to perform.
TROUBLESHOOTING & REPAIR
IGBT/SWITCH BOARD TEST
WARNING
POWER WAVE 450
OR
F-59