Napoleon NBM030S2A Installation And Operating Instructions Manual page 8

9200 series single stage multi position high efficiency (condensing) forced air gas furnace
Table of Contents

Advertisement

8
IOM
IOM
0"
0"
NOTES:
S - Service clearance 24 inches (610mm) or more.
C - Combustible floor (but not carpet or non-ceramic tile).
All models approved for closet installation.
W415-1117 / A / 03.11.14
Plenum
1/2" (13mm)
on all sides
0"
0"
Top
0"
TABLE B - MINIMUM CLEARANCES TO COMBUSTIBLE
MATERIALS (INCHES)
TOP
PLENUM TOP
FRONT
BACK
SIDES
BOTTOM
FLUE PIPE
ENCLOSURE
*24" (610mm) REQUIRED FOR SERVICE
**SUPPLY AIR OUTLET / 1/2" (13mm) RETURN AIR INLET
***CERTIFIED FOR CLOSET INSTALLATION ON COMBUSTIBLE FLOORING.
UPFLOW
HORIZONTAL
0
0
1/2" (13mm)
1/2" (13mm)
0*
0*
0
0
0
0**
0***
0
0
0
CLOSET
CLOSET
H12.11.1