4-2-11 AC Receptacle
AC receptacles are used for taking AC output power from the generator.
A total of 4 kinds of receptacle, each varying in rated voltage and current from another, are
used. As many AC plugs as the receptacles, each matching the corresponding receptacle, are
provided.
The rated current for each receptacle is shown as follows;
CAUTION
Be careful not to use the receptacles
beyond the specified amperage limits to
prevent burning.
MAX
MAX
20A
MAX
20A
AC120V
30A or less
20A or less
Total 50A or less
(RGV12100)
CAUTION
To connect the appliance to the locking
type receptacle, insert the plug in to the
receptacle and then turn it clockwise to
lock.
30A
MAX
30A
MAX
50A
AC 120V / 240V
50A or less
30A or less
30A or less
11
MAX
20A
30A or less
20A or less
Total 30A or less
(RGV13100T)
TWIST