4-2-8 OIL PRESSURE SWITCH
The oil pressure switch sends a signal to ECU to stop the engine when the engine oil pressure
drops to 1.0 kg/cm
2
4-2-9 RELIEF VALVE
The relief valve begins to open when the engine's oil pressure increases above 3.0 kg/cm
RELIEF VALVE
4-2-10 AC SWITCH (NO-FUSE BREAKER)
The AC switch (no-fuse breaker) protects the generator from getting damage by overloading or
short circuit in the appliance. The capacity of AC switch (no-fuse breaker) is as follows ;
Model
RGV12100
RGV13100T
OIL FILTER
OIL PRESSURE SWITCH
Specification
60Hz-120V/240V
60Hz-120V/208V
CAMSHAFT
OIL PUMP
OIL PUMP FILTER
No-fuse Breaker
39A
24A