The power saving mode complies with the VESA Display Power Management Signaling standard. Each state of power management shall be activated
by the host computer terminating the appropriate sync signals. Blanking the video must precede termination of the sync signals. The elapsed time
counter shall also be controlled by the host computer. Reactivation of the monitor shall be accomplished from the host computer by re-establishing the
normal sync signal.
Power consumption
mode
1
Normal operation
2
Active-off (3rd mode)
3
Power-off
* In this mode, the signal will appear in one of three ways: The Horizontal Sync Signal alone off, the Vertical Sync Signal
alone off, or both signals off.
When a failure occurs, the STANDBY/TIMER lamp will ß ash a set number of times to indicate the possible cause of the problem. If there is more than
one error, the lamp will identify the Þ rst of the problem areas.
Status
1
Failure 1
2
Failure 2
3
Failure 3
4
Aging/Self Test
MODE
RESOLUTION 640 X 480 640 X 480 720 X 400 800 X 600 800 X 600 832 X 624 1024 X 768 1024 X 768 1280 X 1024
CLOCK
HORIZONTAL
H. FREQ
H. TOTAL
H. BLK
H. FP
H. SYNC
H. BP
H. ACTIV
VERTICAL
V. FREQ
V. TOTAL
V. BLK
V. FP
V. SYNC
V. BP
V. ACTIV
SYNC
INT (G)
EXT (H/V) / POLARITY
EXT (CS) / POLARITY
SERRATION
SYNC LEVEL
VIDEO
VIDEO LEVEL
SET UP

POWER MANAGEMENT

Screen
Horizontal
(video)
sync signal sync signal consumption
active
yes
blank
no*
--
--

SELF DIAGNOSIS FUNCTION

Area of Failure
HV or +B
H Stop, V Stop or S Correction FET Failure
ABL
TIMING SPECIFICATION
1
2
3
25.175
36
28.322
31.469
43.269
31.469
31.778
23.111
31.777
6.356
5.333
6.355
0.636
1.556
0.636
3.813
1.556
3.813
1.907
2.222
1.907
25.422
17.778
25.422
59.940
85.008
70.087
16.683
11.764
14.268
1.430
0.670
1.557
0.318
0.023
0.381
0.064
0.069
0.064
1.049
0.578
1.112
15.253
11.093
12.711
NO
NO
NO
YES
YES
YES
NO
NO
NO
NO
NO
NO
TTL
TTL
TTL
0.7
0.7
0.7
0
0
0
Vertical
Power
yes
< 100 W
no*
< 3 W
--
0 W (approx)
Amber (0.5 second) / Off (0.5 second)
Amber (1.5 second) / Off (0.5 second)
Amber (0.5 second) / Off (1.5 second)
Amber (0.5 second) / Off (0.5 second)/
Green (0.5 second) / Off (0.5 second)
4
5
6
49.5
56.25
57.283
46.875
53.674
49.725
21.333
18.631
20.111
5.172
4.409
5.586
0.323
0.569
0.559
1.616
1.138
1.117
3.232
2.702
3.910
16.162
14.222
14.524
75.000
85.061
74.550
13.333
11.756
13.414
0.533
0.578
0.865
0.021
0.019
0.020
0.064
0.056
0.060
0.448
0.503
0.784
12.800
11.179
12.549
NO
NO
NO
YES
YES
YES
NO
NO
NO
NO
NO
NO
TTL
TTL
TTL
0.7
0.7
0.7
0
0
0
— 4 —
Recovery time
Indicator
--
Green
Approx. 10 sec.
Amber
--
Off
LED Indication
PRIME
MODE
7
8
9
78.75
94.5
108
60.023
68.677
63.981
16.660
14.561
15.630
3.657
3.725
3.778
0.203
0.508
0.444
1.219
1.016
1.037
2.235
2.201
2.296
13.003
10.836
11.852
75.029
84.997
60.020
13.328
11.765
16.661
0.533
0.582
0.656
0.017
0.015
0.016
0.050
0.044
0.047
0.466
0.524
0.594
12.795
11.183
16.005
NO
NO
NO
YES
YES
YES
NO
NO
NO
NO
NO
NO
TTL
TTL
TTL
0.7
0.7
0.7
0
0