FO-90RA
SW-E1 No. 5 CNG detect time at TEL/FAX mode
The switch which sets the time from the start of CNG detection to the
end of detection.
SW-E1 No. 6 Post answer tone (TEL/FAX mode)
When set to "0", machine send the tones in TEL/FAX auto changeover
mode.
SW-E1 No. 7 Type of post answer tone
When set to "0", post answer tone is 800Hz single tone.
When set to "1", post answer tone is 880Hz/988Hz/1046Hz(LA-SI-DO)
tone.
SW-E1 No. 8 Pseudo ringer ON/OFF cycle
When set to "0", pseudo ringer is 1 sec ON and 2 sec OFF cycles.
When set to "1", pseudo ringer is 1 sec ON and 4 sec OFF cycles.
SW-E2 No. 1 ~ No. 4 Pseudo ringer sound output level to the line
(0~-15dBm setting by 1dBm step)
Used to adjust the sound volume of pseudo ringer to the line (ring back
tone) generated on selecting TEL/FAX.
SW-E2 No. 5 ~ No. 8 Post answer tone transmission level
(0~-15dBm setting by 1dBm step)
Used to adjust the sound volume of post answer tone to the line gener-
ated on selecting TEL/FAX.
SW-E3 No. 1 Reserved
Set to "0"
SW-E3 No. 2, No. 3 Action select when DTMF "#" is received during
phone/fax automatic switching mode
SW-E3 No. 4 ~ No. 8 Reserved
Set to "0".
SW-F1 No. 1, No. 2 DTMF detection time
Used to set detect time of DTMF (Dual Tone Multi Frequency) used in
remote reception(5
).
The longer the detect time is, the less the error detection is caused by
noises.
SW-F1 No. 3 Protection of remote reception (5
Used to set the function of remote reception (5
the remote reception function is disabled.
SW-F1 No. 4 Remote reception with GE telephone
"1": Compatible with TEL mode by GE
"0": Not compatible
• When sending (5
) for remote reception with a GE manufactured
telephone remote reception may not take place because of special
specifications in their DTMF.
To overcome this, a soft SW is provided to change the modem setting
to allow for remote reception.
• If this soft SW is set to "1", other telephone sets may be adversely
affected.
SW-F1 No. 5 ~ No. 8 Remote operation code figure by external TEL
(0~9)
Remote operation codes can be changed from 0 through 9. If set to
greater than 9, it defaults to 9. The "5
Ex- 7
(Default : 5
)
SW-F2 No. 1 CNG detection in STAND-BY mode
When setting to "1", the CNG signal detection function during standby
stops.
SW-F2 No. 2, No. 3 Number of CNG detect (AM mode)
Used for detection of CNG in 1 to 4 pulses.
SW-F2 No. 4, No. 5 Number of CNG detect (STAND-BY mode)
Used for detection of CNG in 1 to 4 pulses.
SW-F2 No. 6 ~ No. 8 Reserved
Set to "0"
) detection
). When set to "1",
" is not changed.
2 – 16
SW-G1 No. 1 ~ No. 8 Reserved
Set to "0"
SW-G2 No. 1 ~ No. 8 Reserved
Set to "0"
SW-G3 No. 1 ~ No. 8 Reserved
Set to "0"
SW-G4 No. 1 ~ No. 6 Quiet detect level setting
(0~-44dBm setting by 1dBm step)
This is used to change the quiet detect level setting.
If quiet detection is difficult due to noise, reduce this setting level.
(Example)
Factory setting : 1 0 1 1 0 0 (- 44dBm)
1 0 1 0 0 0 (- 40dBm)
SW-G4 No. 7 Fax switching when A.M. full
If the answering machine's memory (tape) is full and there is no response,
the machine automatically switches to Fax reception.
SW-G4 No. 8 Reserved
Set to "0".
SW-H1 No. 1 Busy tone continuous sound detect time
Set detecting time busy tone for 5 seconds or 10 seconds.
SW-H1 No. 2 Busy tone detect continuation sound detect during
OGM
Used to detect the continuous tone of specific frequency during OGM
output.
SW-H1 No. 3 Busy tone detect continuation sound detect
Used to select detection of the continuous sound of certain frequency.
SW-H1 No. 4 Busy tone detect intermittent sound detect during OGM
Used to detect the intermittent tone of specific frequency during OGM
output.
SW-H1 No. 5 Busy tone detect intermittent sound detect
Used to select detection of the intermittent sound of certain frequency.
SW-H1 No. 6, No. 7 Busy tone detection pulse number
Used to set detection of Busy tone intermittent sounds.
SW-H1 No. 8 Reserved
Set to "0".
SW-H2 No. 1, No. 2 Busy tone detection ON/OFF time
(Lower duration)
The initial value of detection is set according to electric condition.
The set value is changed according to the local switch board. (Erro-
neous detection of sound is reduced.)
If erroneous detection is caused by sound, etc., adjust the detection
range.
The lower limit can be set in the range of 150msec to 350msec.
SW-H2 No. 3, No. 4 Busy tone detection ON/OFF time
(Upper duration)
Similarly to SW-H1 No. 1, the set value can be varied.
The upper limit can be set in the range of 650msec to 2700msec.
SW-H2 No. 5 Busy tone continuation sound detect frequency
Set detecting frequency of busy tone continuation sound for 320 ~ 570
Hz of 320 ~ 460 Hz.
SW-H2 No. 6 ~ No. 8 Reserved
Set to "0".