Connections And Controls - Pulse Cygnus User Instructions

Laser light effect violet 100mw dpss (405nm)/red 100mw dpss (650nm)
Table of Contents

Advertisement

Connections & Controls:
8
9
1. AC Power Input – This must only be powered from a standard
240VAC, 50~60Hz mains source. Do not use with dimmer packs or
electricity supplies outside this range. A fused power cord must be
used.
2. Min Max – Adjusts sensitivity to sounds within the "bass" range of the
audio spectrum. The sensitivity allows the control over the unit.
3. Safety Hook – Rigging of this device must only be carried out by
competent persons and in accordance with the latest
recommendations. The Safety Hook point is to allow the use of a
correctly rated secondary fixing, the main suspension must be from
the main yoke located on the top of the unit.
4. Power Switch – On/Off mains override
5. Earth Point – As a Class I device this must be earthed, the earth
point can be used when checking the earth continuity during periodic
safety inspections. At no point should the earth be removed from this
device.
6. Cooling Fan – This device uses a fan to maintain its operating
temperature, this must be kept free of obstructions and cleaned as
part of a periodic inspection routine. Cleaning can be done with a non-
conductive brush and low power vacuum cleaner while the unit is
switched off and isolated from the mains supply.
7. Key Switch – The key switch should only be operated by persons
competent with laser operation. When not in use keys should be stored
in a secure position away from the laser device.
8. Function Dip Switches – Select from either Sound Active, Auto or
DMX modes. To set the unit to DMX mode simply set the DMX address
using DIP switches 1 thru 9. For SOUND ACTIVE mode set DIP #10 to
2
3
7
6
4
5
1
6