CHIMNEY INSTALLATION INSTRUC-
TIONS
1. Cut and frame the holes in the ceiling, floor
and roof where the chimney will pass (see
Figure 21). Use a plumb-bob to line up the
center of the holes. The sizes are indicated
in Table 2 for the floor and ceiling holes
and Table 3 (Page 16) for the roof holes.
CHIMNEY MODEL
Secure Temp™ S2100+
Nova Temp™ HT6000+
15 in (380 mm)
Secure Temp GX
ACBI: Ceiling, Floor and Roof
15 in (380 mm)
(1" clearance *)
Wall
17 in (432 mm)
Note: See Table 3 for Sloped Roof Framing
Table 2 - Flat Roof Framing
* The following exception has been approved for
this appliance; The required 2" pipe clearance may
be reduced to a 1" clearance at the ceiling, floor
and roof penetration points for AC chimney only.
All other locations require 2" clearance.
Figure 21 - Roof Framing
1. From below, install a firestop in each ceiling/
floor separation through which the chimney
will pass. At the attic level, install an attic
radiation shield from above (Figures 22a
and 22b).
2. For Secure Temp S2100+ / Nova Temp
HT6000+ / Secure Temp GX chimneys, place
the first chimney length on the fireplace.
To lock it in place, turn 1/4 of a turn clock-
wise. With the ACBI chimney, you must
use a starter section before installing the
first chimney length (Figure 23). Continue
installing chimney lengths making sure to
lock each length in place.
3. Every time the chimney passes through a ceil-
ing or a wall, install the appropriate firestop.
When you reach the desired height, install the
roof support (Refer to instructions included
with the support). For an ACBI chimney use
an universal support AC10SU.
4. Put the roof flashing in place and seal the
joint between the roof and the flashing with
roofing pitch (see Figures 24 and 25). For
sloping roofs, place the flashing under the
upper shingles and on top of the lower
shingles. Nail the flashing to the roof, using
roofing nails.
5. Place the storm collar over the flashing, and
tighten it with the bolt supplied. Finally, seal
the joint between the storm collar and the
chimney, using silicone caulking.
6. Install the chimney cap.
SqUARE HOLE
SIZE OPENING
Figure 22a
CHIMNEY INSTALLATION
MODEL ACBI
Chimney Outside
Air Intake
(required when
using AC chimney)
Figure 23
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
S2100 / HT6000+
Solid Packed Pipe
Attic Radiation Shield
Firestop
Outside Combustion
Air Kit
ACBI
Air Cooled Pipe
Attic Radiation
Shield
Radiation Shield
Figure 22b
Rain Cap
Collar
Flashing
Attic Radiation
Shield
Firestop
Universal Support
ACBI Starter Section
ACBI7SB
or
ACBI7SB30
Note: Outside air kits must be
installed for both fireplace and
ACBI chimney.