Product Specifi C And Important Safety Information; Appliance Certifi Cation; Glass Specifi Cations; Btu Specifi Cations - Heat & Glo RED60-NNN Installation Manual

Hide thumbs Also See for RED60-NNN:
Table of Contents

Advertisement

1 1
Product Specifi c and Important Safety Information
A. Appliance Certifi cation
MODEL: RED60-NNN, RED60-NM, RED60-LM,
RED60-NNN-80, RED60-NM-80, RED60-LM-80
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Heater
STANDARD: ANSI Z21.88-2014/CSA 2.33-2014
Vented Gas Fireplace Heaters
This product is listed to ANSI standards for "Vented Gas
Fireplace Heaters" and applicable sections of "Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles", and "Gas Fired Appliances for
Use at High Altitudes".
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
B. Glass Specifi cations
Hearth & Home Technologies appliances manufactured
with tempered glass may be installed in hazardous lo-
cations such as bathtub enclosures as defi ned by the
Consumer Product Safety Commission (CPSC). The
tempered glass has been tested and certifi ed to the re-
quirements of ANSI Z97.1 and CPSC 16 CFR 1202
(Safety Glazing Certifi cation Council SGCC# 1595 and
1597. Architectural Testing, Inc. Reports 02-31919.01
and 02-31917.01).
This statement is in compliance with CPSC 16 CFR Sec-
tion 1201.5 "Certifi cation and labeling requirements"
which refers to 15 U.S. Code (USC) 2063 stating "...Such
certifi cate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered."
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
4
Heat & Glo • RED60-NNN, RED60-NM, RED60-LM, RED60-NNN-80, RED60-NM-80, RED60-LM-80 Installation Manual • 2159-970 Rev. H • 3/15
C. BTU Specifi cations
Models
(U.S. or Canada)
RED60-NNN
US
(0-2000 FT)
RED60-NM
RED60-LM
RED60-NNN-80
CANADA
RED60-NM-80
(2000-4500 FT)
RED60-LM-80
(NG)
RED60-NNN
US
(0-2000 FT)
RED60-NM
RED60-LM
RED60-NNN-80
CANADA
RED60-NM-80
(2000-4500 FT)
RED60-LM-80
(PROPANE)
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
• In CANADA: Reduce input rate 10% for elevations
between 2000 feet and 4500 feet. Above 4500 feet,
consult local gas utility.
Check with your local gas utility to determine proper
orifi ce size.
E. Non-Combustible Materials Specifi cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in
a Vertical Tube Furnace at 750 ºC shall be considered
non-combustible materials.
F. Combustible Materials Specifi cation
Materials made of or surfaced with wood, compressed pa-
per, plant fi bers, plastics, or other material that can ignite
and burn, whether fl ame proofed or not, or plastered or
unplastered shall be considered combustible materials.
G. Electrical Codes
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
• A 110-120 VAC circuit for this product must be pro-
tected with ground-fault circuit-interrupter protection,
in compliance with the applicable electrical codes,
when it is installed in locations such as in bathrooms
or near sinks.
Minimum
Orifi ce
Maximum
Input
Size
Input BTU/h
BTU/h
(DMS)
44,000
31,000
#30
39,500
28,000
#32
43,000
35,000
#47
38,500
31,500
#48

Advertisement

Table of Contents
loading

This manual is also suitable for:

Red60-lm-80Red60-nmRed60-lmRed60-nnn-80Red60-nm-80

Table of Contents