Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless
testing requires power.
Illustration
Pressure regulator
Spark module
4 + 0
Input
GND
L or N
Holder orifice
Spark ignition
electrode
270° valve
Spark 270° switch
Top surface burner
©2003 Maytag Appliances Company
!
Component
Verify gas pressure (WCP).
If on LP service, verify proper gas
supply conversion.
Test for voltage at terminals
L and N...........................................
Polarity and ground ........................
Verify gas pressure (WCP).
Check orifice for debris.
Test for resistance of spark lead ..........
Test ignitor to chassis ..........................
Verify gas is supplied.
Verify Orifice for
Natural or LP.
Adjust set screw for simmer control.
Unplug switch harness at rear of
range. Test for continuity at wire
terminals.
Switch in LITE position .......................
Switch in any other position................
Verify gas is supplied ...........................
Verify burner cap is positioned
correctly.
16022498 Rev. 0
WARNING
Test Procedure
Results
4
Natural
"
10
LP/Propane
"
120 VAC
Not subject to polarity
4
Natural
"
10
LP/Propane
"
Clean as needed.
Continuity
No continuity from ignitor to chassis.
Fixed orifices for Natural or LP.
See conversion section.
120 VAC
Continuity
Infinite
Check for obstructions in burner ports.