Minimum Clearance To Combustibles - Napoleon Castlemore GDS26N Installation And Operating Instructions Manual

Table of Contents

Advertisement

30
4.4

MINIMUM CLEARANCE TO COMBUSTIBLES

Minimum clearance to combustible construction from appliance and vent surfaces:
-
A
-
B
-
C
Combustible Framing:
-
-
NOTE: Appliance should not be installed directly on
carpeting.
Rear Exit:
-
Top Exit:
-
* HORIZONTAL VENT SECTIONS:
A minimum clearance of 1" at the bottom and sides and 2" at the top of the vent pipe in all horizontal runs to
combustibles is required. Use fi restop spacer W010-1313 and shield W585-0240 (supplied).
* VERTICAL VENT SECTIONS:
A minimum of 1" all around the vent pipe on all vertical runs to combustibles is required. Use fi restop spacer
W010-1313 (supplied).
** For top vent vertical termination, see "REAR EXIT" for specifi c clearances.
At a distance of 2" from the wall, installation or service to the blower may not be practical. A minimum of 5" will
be required in order to install or service the blower.
REAR EXIT
The appliance requires a minimum ceiling height of 47 1/2" for a rear vent. For temperature requirements, the
space around and above the appliance must be left unobstructed.
W415-0827 / A / 06.07.10
2"
5"
2"
1" to bottom and sides of the vent pipe*
2" to top of the vent pipe*
47 1/2" to ceiling from base of the appliance
51" to ceiling from base of the appliance**
COMBUSTIBLE
MANTEL, SHELF,
OR CEILING
12"
47 1 /2"
35 1 /2"
NON-COMBUSTIBLE
BRICK
0" IF
NON-COMBUSTIBLE
FINISHING IS USED
2"
SUCH AS BRICK AND
STONE.
1"
29 1 /8"
MINIMUM
PLUS RISE *
5"
BACK WALL
BACK WALL

Advertisement

Table of Contents
loading

This manual is also suitable for:

Castlemore gds26p

Table of Contents