'LVDVVHPEO\

Disassembly

Indoor Unit
Disconnect the unit from power supply before mak-
ing any checks.
Be sure the power switch is set to "OFF".
1.Disassemble the front panel
Open the front panel, slightly press the both sides of rotating axial
of the panel, to make the rotating axial out of groove, can take down
the front panel.
To push the filter forward, to make the both clasps loosen, can pull
Screw off one screw from the top cover, can take down it.
out off the filter.
2.Disassemble the air guide louver
To make the axis sleeve out of the middle of left air guide louver,
hold both sides of air guide louver, slightly press the middle part
then can disassemble the air guide louver.
3.Disassemble the front case
Screw off 7pcs screw from fixing front case, loosen the clasps of
rear side, lift it up, can disassemble the front case.
178
Front panel
Filter
Axis sleeve
Air guide board
Screws
Clasps
Top cover