In the heating-run, to prevent the indoor fan from blowing cold air, the indoor fan will stop
or run slowly until the coil is warmth.
3.8 blow waste heating and waste cooling function
The heating mode, remote shutdown, such as indoor heat exchanger temperature is
higher, the wind blowing out opportunities continue to run the waste heat.
Cool and dehumidification mode , after the compressor close, indoor machine will
continue to set the speed of operation for a period of time.
3.9 automatically model
This model does not automatically model function, emergency button cannot set the
automatic mode of operation, can use the emergency switch shutdown, remote setting the
automatic mode of indoor machine with remote signal.
3.10 Dehumidifying method:
Remote control setting dehumidifying mode, indoor machine forced to run at low
speed(high power key or a strong bond also maintain a low wind speed), the outdoor
machine according to the refrigeration mode operation.
3.11 Fault display
If the product operation failure, outdoor and indoor display control panel lights will quote
fault.