Desa (V)B36 Owner's Operation And Installation Manual page 6

Wood burning fireplace
Table of Contents

Advertisement

MANTELS
A mantel may be installed if desired (see
Figure 4). Woodwork such as wood trims,
mantels or any other combustible material
projecting from front face must not be placed
within 9" of fireplace opening (and within 9"
of top louver opening). Combustible materi-
als above 9" and projecting more than 1
from fireplace must not be placed less than
12" from top opening of fireplace (NFPA STD
211, Sec. 7-3.3.3).
Mantels or any other combustible material
may come up to side edge of black metal face
of fireplace if projection from front face falls
within limits shown in Figure 5.
12
/
" Ref.
1
4
6"
Ref.
33°
3" Nom.
12"
1
Min.
Max.
6"
Min.
9"
Min.
Top of
Louvered
Opening
Fireplace Opening
Figure 4 - Mantel Clearances to
Combustible Material
Top View of Fireplace
SAFE ZONE
9"
33°
Min. 12" from
Perpendicular Side Wall
Figure 5 - Side Mantel Clearance
6
FIREPLACE INSTALLATION
Combustible
Material
Safe Zone For
Projection of
Combustible
Materials
*Note: Drawing
Not To Scale
/
"
1
2
Upper Section
of Circulating
Fireplace
FIREBOX
0.625" Max.
1"
www.fmiproducts.com
Continued
FAN/BLOWER KIT ASSEMBLY
Fan or blower kit is optional with this fireplace
(for circulating models only). Use of blowers
or fans other than those manufactured by
FMI PRODUCTS, LLC voids warranty. Fan
is operated by pressing rocker switch (see
Figure 6) in lower right hand corner of fireplace
/
"
face. Blower is operated by turning control
1
2
knob (not shown).
Fan/blower kit electrical connections are
made through electrical cover plate on side
of fireplace a shown in Figure 6.
Rocker
Switch
Wire Nut (3x)
Electrical
(Not Supplied)
Housing
Receptacle
(Supplied)
Prewired Receptacle
and Ground
Figure 6 - Fan Switch-Electrical Bushing
Wiring Instructions
1. Remove electrical cover plate with bush-
ing from fireplace by removing 2 sheet
metal screws as shown in Figure 6.
2. Slide power source wiring through electri-
cal bushing opening and electrical cover
plate and make all necessary connec-
tions.
3. Slide all wiring connections in electrical
housing as shown in Figure 6.
4. Secure electrical cover plate with screws
previously removed.
Note: Electrical housing and cover plate have
sharp edges. Wear protective gloves.
Sheet
Metal
Screws
Electrical
Electrical
Cover
Bushing
Plate
Outer Wrapper
of Fireplace
Power Source Wiring
(Not Supplied)
To Power
Source
Electrical Cover
Plate and
Electrical Bushing
Fireplace Chassis
Ground
109034-01M

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

(v)b36l(v)b36i(v)b36li

Table of Contents