Connect The Electrical Components; Connect The 10 Volts Ac Supply; Connect The 1 Volts Dc Supply - Norcold N61X Installation Manual

6/8 cu.ft. 2 way
Hide thumbs Also See for N61X:
Table of Contents

Advertisement

Available languages

Available languages

!
CAUTION:
Apply Loctite removable thread locker (blue)
to the threads of the hinge screws before assembly to
prevent loosening during use. Do not allow Loctite to
contact any of the plastic surfaces of the refrigerator
because it can damage those surfaces.
- Align the hinges and put the hinge pins into each door.
- Tighten the hinge pins.
- Put the storage bins in the doors.

Connect the Electrical Components

AC Operation
10 volts AC voltage
1 volts DC control voltage
This refrigerator operates on these electrical sources. Operation
out of these limits may damage the refrigerator's electrical circuit
parts and will void the warranty.
!
WARNING:
The rear of the refrigerator cooling system
has hot surfaces and sharp surfaces that can damage
electrical wiring. Make sure that there is a good clearance
between all electrical wiring and the cooling system of
the refrigerator. Position any electrical wiring within the
refrigerator enclosure opposite the burner side of the
refrigerator. Do not put any electrical wiring through the
roof exhaust vent. Failure to correctly position electrical
wiring can result in electrical shock or fire.
Connect the 120 volts AC supply:
!
WARNING:
Connect the AC power cord(s) only to a
grounded three-prong receptacle. Do not remove the
round ground prong from any of the AC power cords. Do
not use a two prong adapter or an extension cord with
any of the AC power cords. Operation of the refrigerator
without correct ground can cause dangerous electrical
shock or death if you are touching the metal parts of the
refrigerator.
Put the AC power cord(s) into a grounded three-prong receptacle:
- Make sure the receptacle is positioned within easy reach of
the lower intake vent.
- Make sure the power cord(s) does not touch the burner
cover, the flue pipe, or any hot component that could
damage the insulation of the power cord.
(1 volts max. - 108 volts min.)
(15.4 volts max. - 10.5 volts min.)
Connect the 12 volts DC supply:
As the distance from the vehicle battery to the refrigerator
increases, the correct AWG wire size and fuse size also
increases. If the wire size is too small for the distance, a voltage
drop occurs.
1. Determine the min. wire size and the max. fuse size to use:
!
WARNING:
If you use an incorrect wire size and/or fuse
size, electrical fire can result.
- Use a minimum of 18 AWG wire and a maximum 6 Amp fuse.
- If the wire size is larger than the min. size, use the correct
fuse per RVIA A119. standard or local codes.
. Install a fuse in DC power supply wires between the battery
and the refrigerator:
- Put fuse as close to the battery as possible.
. Connect the DC power supply wires (See Art00966):
- Attach a 1/4 inch Quick Connect terminal to each DC power
supply wire.
NOTE: Do not use the chassis of the refrigerator or the vehicle
frame as one of the conductors. Attach the DC power
supply wires only to the battery and the power board
[49] of the refrigerator.
- Push the positive DC power wire [50] onto the power board
terminal that is marked 12VDC.
- Push the DC ground wire [51] onto the power board terminal
that is marked GND.
- Make sure each DC power supply wire is on the correct
polarity terminal.
Installation Manual 9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

N81x

Table of Contents