General Data - LG ARNU073TUC4 Instruction Manual

Multi v ceiling cassette indoor unit
Table of Contents

Advertisement

Type
Cooling Mode Performance
Capacity (Btu/h)
Power Input
(W)
1
Heating Mode Performance
Capacity (Btu/h)
Power Input
(W)
1
Entering Mixed Air
Cooling Max (°F WB)
Heating Min (°F DB)
Unit Data
Refrigerant Type
2
Refrigerant Control
Net Unit Weight (lbs)
Shipping Weight (lbs)
Grille Weight (lbs)
Grille Shipping Weight (lbs)
Communication Cable
3
(No. x AWG)
Fan
Quantity
Airflow Rate H/M/L (CFM)
Piping
Liquid Line (in, OD)
Vapor Line (in, OD)
Condensate Line (in, ID)
Power Input is rated at high speed.
1
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or
2
destroy R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F)
under section 608 of CAA.
All communication cable to be minimum 18 AWG, 2-conductor, stranded, shielded and
3
must comply with applicable local and national codes. Ensure the communication cable
is properly grounded at the master outdoor unit only. Do not ground the ODU−IDU com-
munications cable at any other point.
EEV: Electronic Expansion Valve
Power wiring is field supplied and must comply with the applicable local and national
codes. Power Supply (V/Hz/Ø): 208-230/60/1
Table 2: 4-Way Cassette Indoor Units Specifications
4-Way Ceiling Cassette – 2 ft x 2 ft Models – TR/TQ Chassis
ARNU053TRC4
ARNU073TRC4
5,500
7,500
30
30
6,100
8,500
30
30
76
76
59
59
R410A
R410A
EEV
EEV
29
29
34
34
7
7
11
11
2 x 18
2 x 18
1
1
265 / 247 / 212
265 / 247 / 212
1/4 Flare
1/4 Flare
1/2 Flare
1/2 Flare
1
1
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
ARNU093TRC4
ARNU123TRC4
9,600
12,300
30
30
10,900
13,600
30
30
76
76
59
59
R410A
R410A
EEV
EEV
32
32
38
38
7
7
11
11
2 x 18
2 x 18
1
1
283 / 265 / 251
307 / 283 / 247
1/4 Flare
1/4 Flare
1/2 Flare
1/2 Flare
1
1
This unit comes with a dry nitrogen charge.
This data is rated 0 ft above sea level, with 25 ft of refrigerant line per indoor unit and a 0 ft
level difference between outdoor and indoor units. All capacities are net with a combina-
tion ratio between 95-105%.
Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and
67ºF wet bulb (WB) and outdoor ambient conditions of 95ºF dry bulb (DB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and
outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).

GENERAL DATA

Specifications
ARNU153TQC4
ARNU183TQC4
15,400
19,100
30
17,100
21,500
30
76
59
R410A
R410A
EEV
EEV
35
40
7
11
2 x 18
2 x 18
1
388 / 353 / 328
396 / 388 / 353
1/4 Flare
1/4 Flare
1/2 Flare
1/2 Flare
1
30
30
76
59
35
40
7
11
1
1
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents