READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a quali-
fied person(s) in accordance with all applicable codes and stan-
dards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further informa-
tion and requirements.
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 3.
®
®
LOSONE SELECT
®
L200 SERIES • L250 SERIES • L300 SERIES
TABLE OF CONTENTS
This manual is divided into sections as follows:
• "WARRANTY"
• "TYPICAL INSTALLATION"
This section shows a common installation in new and existing,
frame construction.
- Mounting (new construction)
- Mounting (existing construction)
- Wiring
- Ducting (horizontal blower discharge)
• "MOUNTING OPTIONS"
• "WIRING OPTIONS"
-Wiring Plate Position
• "DUCTING OPTIONS"
- Blower Discharge Positions
- Ducting (vertical blower discharge)
• "USE AND CARE"
• "SERVICE PARTS"
WARRANTY
BROAN-NUTONE CANADA ONE YEAR LIMITED WARRANTY
Broan-NuTone Canada warrants to the original consumer purchaser of its products
that such products will be free from defects in materials and workmanship for
a period of one year from the date of original purchase. THERE ARE NO
OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, BUT NOT
LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone Canada will, at its option, repair
or replace, without charge, any product or part which is found to be defective
under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS
AND TUBES. This warranty does not cover (a) normal maintenance and service
or (b) any products or parts which have been subject to misuse, negligence,
accident, improper maintenance or repair (other than by Broan-NuTone Canada),
faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as
specified for the express warranty.
BROAN- NUTONE CANADA'S OBLIGATION TO REPAIR OR REPLACE, AT
BROAN-NUTONE CANADA'S OPTION, SHALL BE THE PURCHASER'S SOLE
AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE
CANADA SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR
SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT
USE OR PERFORMANCE. Some jurisdictions do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary by jurisdiction. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone Canada at
the address or telephone number below, (b) give the model number and part
identification and (c) describe the nature of any defect in the product or part. At
the time of requesting warranty service, you must present evidence of the
original purchase date.
Broan-NuTone Canada Inc.
1140 Tristar Drive, Mississauga, Ontario L5T 1H9 (1-888-882-7626)
L100 SERIES • L150 SERIES
Page 1
99042810

Advertisement

loading

Summary of Contents for Broan L100 SERIES

  • Page 1 This warranty gives you specific legal rights, and you may also have other rights, which vary by jurisdiction. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone Canada at the homeowner. the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part.
  • Page 2: Typical Installation

    LOSONE SELECT L100 SERIES • L150 SERIES ® L200 SERIES • L250 SERIES • L300 SERIES ® Page 2 TYPICAL INSTALLATION TYPICAL INSTALLATION MOUNTING (New Frame Construction) WIRING Mounting brackets BLACK ROUND DUCT* factory-shipped in position for ½” BLACK TOP / BACK (12.7 mm) ceiling...
  • Page 3: Mounting Options

    LOSONE SELECT L100 SERIES • L150 SERIES ® L200 SERIES • L250 SERIES • L300 SERIES ® Page 3 MOUNTING OPTIONS DUCTING OPTIONS BLOWER DISCHARGE POSITIONS ¼-20 hex nuts secure mounting brackets to housing. Loosen and re-tighten or remove and replace nuts as necessary for desired mounting bracket position.
  • Page 4 LOSONE SELECT L100 SERIES • L150 SERIES ® L200 SERIES • L250 SERIES • L300 SERIES ® Page 4 SERVICE PARTS SERVICE PARTS KEY NO. PART NO. DESCRIPTION 97014725 Housing Assembly (L100’s & L150’s) 97014726 Housing Assembly (L200’s thru L300’s) 97014728 Mounting Bracket (2 req.)
  • Page 5 Cette garantie annule Installateur: Remetez ce manuel au toutes les garanties précédentes. Pour le service sous garantie, vous devez (a) aviser Broan-NuTone Canada protpriétaire de maison. á l’adresse ou au numéro de téléphone ci-dessous, (b) donner le numéro du modèle et l’identification de la pièce et (c) décrire la nature de tout défaut...
  • Page 6 LOSONE SELECT LOSONE SELECT L100 SERIES • L150 SERIES SÉRIE L100 • SÉRIE L150 ® ® L200 SERIES • L250 SERIES • L300 SERIES SÉRIE L200 • SÉRIE L250 • SÉRIE L300 ® Page 6 INSTALLATION TYPIQUE INSTALLATION TYPIQUE MONTAGE (Construction en cours) CÂBLAGE...
  • Page 7 LOSONE SELECT LOSONE SELECT L100 SERIES • L150 SERIES SÉRIE L100 • SÉRIE L150 ® ® L200 SERIES • L250 SERIES • L300 SERIES SÉRIE L200 • SÉRIE L250 • SÉRIE L300 ® Page 7 OPTIONS D’INSTALLATION DES CONDUITS OPTIONS DE MONTAGE Des écrous à...
  • Page 8 LOSONE SELECT L100 SERIES • L150 SERIES LOSONE SELECT SÉRIE L100 • SÉRIE L150 ® ® L200 SERIES • L250 SERIES • L300 SERIES SÉRIE L200 • SÉRIE L250 • SÉRIE L300 ® Page 8 PIÈCES DE RECHANGE PIÈCES DE RECHANGE LÉGENDE N...

This manual is also suitable for:

L150 seriesL200 seriesL250 seriesL300 series