Daikin FAQ100BUV1B Operation Manual
Daikin FAQ100BUV1B Operation Manual

Daikin FAQ100BUV1B Operation Manual

Split system wall mounted type
Hide thumbs Also See for FAQ100BUV1B:

Advertisement

SPLIT SYSTEM

MODELS
(Wall mounted type)
FAQ100BUV1B
FAQ100BVV1B

OPERATION MANUAL

Air Conditioner
English
Deutsch
Français
Español
Italiano
ÅëëçíéêÜ
Nederlands
Portugues
Ðóññêèé

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FAQ100BUV1B

  • Page 1: Operation Manual

    OPERATION MANUAL English SPLIT SYSTEM Air Conditioner Deutsch MODELS Français (Wall mounted type) FAQ100BUV1B Español FAQ100BVV1B Italiano ÅëëçíéêÜ Nederlands Portugues Ðóññêèé...
  • Page 3 τηλεχειριστηρßου για λεπτοìÝρειεò σχετικÜ ìε τα ονüìατα και τιò λειτουργßεò των διακοπτþν και των οθονþν του τηλεχειριστηρßου. Wij danken u voor de aankoop van deze Daikin air- Vielen Dank für den Kauf einer Klimaanlage von conditioner. Lees deze bedrijfshandleiding aan- Daikin.
  • Page 4: Table Of Contents

    The unit is individually operated. 1. WHAT TO DO BEFORE OPERA- NOTE TION • Contact your Daikin dealer in case of changing the combination or setting of group control and This operation manual is for the following systems two remote controller control systems.
  • Page 5: Safety Considerations

    ant does not exceed the limiting concentration 2. SAFETY CONSIDERATIONS even when it leaks. If the refrigerant leaks exceeding the level of limiting concentration, an We recommend that you read this instruction man- oxygen deficiency accident may happen. ual carefully before use to gain full advantage of the function of the air conditioner, and to avoid malfunc- For installation of separately sold compo- tion due to mishandling.
  • Page 6: Operation Range

    Do not operate the air conditioner with a wet COOLING hand. INDOOR OUTDOOR An electric shock may result. OUTDOOR TEMPERA- TEMPERA- Do not place items that might be damaged by UNIT HUMIDITY TURE TURE water under the indoor unit. 18 to 37 Water may condensate and drip if the humidity 80% or RZQ100...
  • Page 7: Operation Procedure

    A. Up and down adjustment • Operating procedure varies with heat pump type B. Left and right direction and cooling only type. Contact your Daikin dealer to confirm your system type. A. UP AND DOWN DIRECTION • To protect the unit, turn on the main power switch 6 hours before operation.
  • Page 8: Optimum Operation

    MOVEMENT OF THE AIR FLOW FLAP 6. OPTIMUM OPERATION For the following conditions, micro computer con- Observe the following precautions to ensure the trols the air flow direction so it may be different from system operates. the display. • Adjust the room temperature properly for a com- fortable environment.
  • Page 9 HOW TO CLEAN THE AIR FILTER HOW TO CLEAN AIR OUTLET AND OUT- SIDE PANELS Clean the air filter when the display shows “ ” . • Clean with soft cloth. Increase the frequency of cleaning if the unit is •...
  • Page 10: Not Malfunction Of The Air Conditioner

    It is necessary to clean the I. If one of the following malfunctions occurs, inside of the indoor unit. Ask your Daikin dealer take the measures shown below and contact for details on cleaning the unit. This operation your Daikin dealer.
  • Page 11 • If direct sunlight enters the room (when cool- MALFUNCTION ing). CODE Use curtains or blinds. Measure: Notify your Daikin dealer and inform • When there are too many inhabitants in the room (when cooling). him/her of the display. Cooling effect decreases if heat gain of the II.
  • Page 12 3P083810-7V EM03A092B (0510) HT...