Amana ALD10DT P1331001M Service Manual page 12

Countertop commercial microwave ovens
Table of Contents

Advertisement

Troubleshooting Procedures (Electronic Models)
Trouble 2:
Display shows all figures selected, but does not start cooking even though
desired program and time is set when the START pad is pressed.
CONDITION
Oven lamp
does not turn
on
Check continuity of secondary
supplied to RELAY (RY2) coil
12
CHECK
Check continuity of primary
interlock switch
interlock switch
Check D.C. voltage being
RESULT
No
Continuity
primary interlock
No
Continuity
0 V
Failed touch
Approx.
Faulty contacts of
15 VDC
RELAY (RY2) or
open relay coil
16400005
CAUSE
REMEDY
Adjust or
Malfunction of
replace
switch
Adjust or
Malfunction of
replace
secondary
interlock
switch
Replace
Panel
Replace
Control
Board
©2009 ACP Inc.