Option 1: 3-Wire Connection with
a Power Supply Cord
If your local codes or ordinances
permit the
connection
of a frame-grounding
conductor
to the
neutral wire, use these instructions.
If your local
codes or ordinances
do not allow the connection
of
a frame-grounding
conductor
to the neutral wire,
use the instructions
under Section
3: Optional
3-wire connection.
C
g
f
a.
3-wire receptacle (NEMA type !0-30R)
b.
3-wire plug
c.
Neutral prong
d.
Spade terminals with up turned ends
e.
3/4 in. ( !.9 cm) UL approved strain relief
f.
Ring terminals
g.
Neutral (white or center wire)
.
2.
Loosen or remove center terminal
block screw.
Connect neutral wire (white or center wire) of
power supply cord to the center, silver colored
terminal
screw of the terminal block.
Tighten
screw.
O
O
a.
External ground connector
b.
Neutral grounding wire (white)
c.
Center silver-colored
terminal block screw
d.
Neutral wire (white or center wire)
e.
3/4in. (!.9cm)
UL-listed strain relief
3. Connect the other wires to outer terminal block
screws. Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of
dryer rear panel. Secure cover with hold-down
screw.