STEP 4: Connection
of Gas Supply
(Gas dryer only).
In addition
to the following,
please refer to manual section on Gas Requirements
and Instructions.
ii
i
1. New stainless
steel flexible
connector.
Use this type of
connector
only if allowed
by local codes.
Use Design AGA
Certified
Connector.
2. 1/8" NPT Pipe Plug (for checking
inlet gas pressure)
3. Equipment
Shut-Off
Valve-
Installed
within 6' ( 1.8 m) of dryer
4. Iron Pipe.
Shorter
than 20'
(6,1 m)
Use 3/8" pipe.
Longer
than 20' (6.1 m) - Use 1/2" pipe.
5.3/8"
N.P.T.
Gas Conuection
1. Confirm
that the type of gas available
in your
laundry room is appropriate
for the dryer. The
dryer is prepared
for Natural Gas with a 3/8"
NPT gas connection.
2. Remove the shipping cap from the gas
connection
at the back of the dryer.
Make sure
that you don't damage the threads of the gas
connection
pipe when you remove the shipping
cap.
3. Connect the dryer to your laundry room's gas
supply using a new flexible
stainless
steel
connector
(as noted below, only use a new
stainless
steel flexible
connector
if allowed by
your local codes).
4. Securely
tighten all connections
between
the
dryer and your laundry room's
gas supply.
Turn
on your laundry room's gas supply and check all
pipe connections
(both internal and external)
for
gas leaks with a non-corrosive
leak detection
fluid.
5. For LP (Liquefied
Petroleum)
gas connection,
refer to this manual's
section entitled Gas
Requirements
and Instructions.
10
STEP 5: Electrical Plug Connections
for Electric Dryer Only•
Following
are several warnings
and instructions
concerning
making the electrical
connection
for
electric dryers.
More detailed
information
concerning
the electrical
connection
is provided
at
the manual
section entitled Electrical
Requirements
For Electric Dryer and it is important
that you
thoroughly
review that section, and the remainder
of
this manual, before taking any steps to install or use
this dryer.
1. Use only a new U.L. listed No. 10 (copper wire
only) three conductor
power supply cord kit rated
240 Volts (minimum)
30 Amperes
and labeled as
suitable for use in a clothes dryer.
2. Four-wire
cord is requited
for manufactured
(mobile)
home installations
and use and where
local codes do not allow grounding
of this
appliance
through neutral.
3. Thc wiring diagram
is providcd
insidc thc drycr
control hood.
Label all wires prior to
disconnection
when servicing
the dryer, because
wiring errors can cause serious injury to you and
your dryer.
4. For additional
instruction
on connecting
the dryer
to an electrical
power source, please refer to this
manual's
section on Electrical
Requirements
and
Electric Dryer.
WARNING!
• Use a new UL approved
30 amp power
supply cord or 10 gauge solid copper
wire.
• Use a UL approved
strain relief.
• Disconnect
power before making
electrical
connections.
• Connect
neutral wire(wh ite or center wire) to
center terminal.
• Ground
wire(green
or bare
wire) must be
connected
to green ground connector.
• Securely
tighten all electrical
connections
• See installation
instructions
for complete
instructions.
• Failure to do so can result in fire or electrical
shock.