Important Operating Notes:

● If the cowl is positioned close to an opening hatch (window), keep this closed during operation . See
warning plate.
Always mount the cowl cover if the heater is not being used.
Non observation of this point can lead to the function of the
appliance being impaired through water, dirt or insects.
● Always remove the cowl cover prior to operating the water
heater on gas.
● Only use original Truma-Ultrastore parts.
● If just the cold water system is being used, without water
heating, the header tank becomes more vulnerable to frost
damage. Accordingly the contents should be drained by
operating the safety/ drain valve. This also applies when the
caravan is in storage.
● If the water heater is inadvertently operated empty the caravan
will trip out. To reset, turn off 5 and 10 amp trips, turn off RCD consumer unit, then fill with water and
turn 5 amp trip back on.
● The excess temperature thermostat will cut in on the heater on 230V if there is a fault. It will also
reset if disconnected from the mains. However this may not happen if there is no water in the tank.
4.1.8

General Safety Notes:

▲ In the event of leaks in the gas systems or if there is a smell of gas:
- Extinguish all naked flames
- Do not smoke
- Switch off the appliance and the gas cylinder
- Open the windows
- Do not operate any electrical switches
- Have the entire system checked by an expert
● Repair jobs are only to be carried out by an expert.
● The following would invalidate the guarantee;
a. Any alteration to the appliance (including cowl)
b. The use of non-Truma spare parts/ accessories
c. Non observance of the operating instructions
● The operating pressure for the gas supply is 30mbar (or for 28mbar butane / 37 mbar propane) and
must correspond to the operating pressure of the appliance (see name plate).
● Do not operate the water heater when refuelling the vehicle and when in the garage.
● During the initial operation of a brand new appliance (or after it has not been used for some time), a
certain amount of fumes and a slight smell may be noticed for a short time. Remedial action here is
to immediately run the heater at maximum output and to ensure adequate room ventilation.
● If the burner makes an unusual noise or if the flame lifts off, it is likely that the regulator is faulty and
it is essential to have it checked.