Activated Carbon Filter - Bosch DHZ 2100 Operating And Installation Instructions

Table of Contents

Advertisement

Filters and maintenance
Important:
Metal filters that are heavily saturated with
grease should not be cleaned at the same
time as any crockery, etc.
❑ If the filter mat is going to be cleaned by
hand, soak it first of all in a hot deter-
gent solution for several hours.
Clean the filter with a brush, rinse it off
thoroughly and allow it to drip dry.
❑ Use only original replacement filters.
In so doing you will be ensuring that the
extractor hood performs as effectively
as possible.
Removing and installing the grease
filter
Extractor hoods with a filter mat
1. Rotate the handles on the left and right
of the filter grille.
2. Press the retaining spring and remove
the filter frame.
3. Remove the wire grille and replace the
filter mat.
4. Install the filter frame in reverse sequence.
Re-attach the retaining spring.
The left and right sides of the filter
frame must lock into position!
4
Extractor hoods with two filter cartridges:
Warning: The halogen bulbs must be swit-
ched off and cool.
1. Depress the detent on the grease filters
in the direction of the arrow and fold
down the grease filter slightly. Detach
the grease filter by pulling it towards
yourself.
:
2. Clean the grease filters.
3. Re-insert the clean grease filters.

Activated carbon filter

Removing and installing the activa-
ted carbon filter
Extractor hoods with a filter mat:
1. Remove the filter; see grease filter.
❑ The wire grille is no longer required
when an activated carbon filter is
installed.
2. Place the activated carbon filter on the
filter mat and clamp it in.
3. Install the filter frame.
❑ See grease filter.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dhz 7204Dhz 7304Dhz 7305