Superior VRE4336ZEN Installation Instructions Manual

Outdoor decorative gas fireplace

Advertisement

OUTDOOR DECORATIVE GAS FIREPLACE
P/N 506009-24 REV. NC 03/2014
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certified kit is used.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour consula-
tion ultérieure.
WARNING: DO NOT store or use gasoline or other
flammable vapors or liquids in the vacinity of this or
any other appliance.
DANGER
WARNING: For
Outdoor Use Only.
DANGER
IF YOU SMELL GAS:
1. Shut off gas to appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from the appli-
ance and immediately call your gas supplier
or your fire department.
C
US
CARBON
MONOXIDE
HAZARD
This appliance can pro-
duce carbon monoxide
which has no odor.
Using it in an enclosed
space can kill you.
Never use this appli-
ance in an enclosed
space such as a camp-
er, tent, car or home.
PFS Report No. 14-020

INSTALLATION INSTRUCTIONS

OUTDOOR DECORATIVE GAS FIREPLACE
MODELS
VRE4336ZEN
VRE4336ZEP
A French manual is available upon request. Order Form Number
506009-25.
Ce manuel d'installation est disponible en francais, simplement en
faire la demande. Numéro de la pièce 506009-25.
WARNING: Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage. Read the in-
stallation, operating and maintenance instructions thoroughly before
installing or servicing this equipment.
DANGER
Avertissement:
Pour utilisation à
l'exérieur seule-
ment.
DANGER
SI VOUS UNE ODEUR DE GAZ:
1. Coupez l'admission de gaz de l'appariel.
2. Éteindre toute flamme nue.
3. Si l'odeur persiste, éloignez-vous de
l'appareil et appelez immédiatement votre
fournisseur de gaz ou le service d'incendie.
P506009-24
VRE4342ZEN
VRE4342ZEP
MONOXYDE
DE CARBONE
Cet appareil peut
produire du monoxyde
de carbone, un gaz
inodore.
Son utilisation dans un
espace clos peut vous
tuer.
Ne jamais utiliser cet
appareil dans un es-
pace clos, tel qu'une
caravane, tente, voiture
ou à la maison.
1

Advertisement

Table of Contents
loading

Summary of Contents for Superior VRE4336ZEN

  • Page 1: Installation Instructions

    P506009-24 indicated on the rating plate. This appliance is MODELS not convertible for use with other gases, unless a certified kit is used. VRE4336ZEN VRE4342ZEN VRE4336ZEP VRE4342ZEP INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 3 - three (3) bags of volcanic stone, envelope These appliances are designed to operate on is located in the firebox area. natural gas or propane. An electronic inter- 4 - Electrical kit containing the wall switch mittent pilot ignition system provides safe, Packaging .........page components, battery holder, box and cover...
  • Page 3: Massachusetts Requirements

    Input is shown in Table 1: sures equal to or less than 1/2 psi (3.5 kPa). BTU Input (BTU/Hr) Model No. Input Rate (BTU/Hr) Natural Gas VRE4336ZEN 50,000 to 39,500 VRE4342ZEN 50,000 to 39,500 Propane Gas (LP) VRE4336ZEP 46,000 to 37,000...
  • Page 4: Location

    ASSEMBLY OUTLINE Carefully consider the position of the fireplace ASSEMBLY STEPS opening with respect to the location of adjacent Before You Start NOTE: The following steps represent the normal or nearby stairwells, doors, windows, walkways and over hanging trees, patios and wires. sequence of installation.
  • Page 5 When Planning for the installation of the fire- place, the framing height must be increased from 46-1/2" to 47-1/4", when installing the drain pan. An additional space below the fireplace will also be required to plumb a Threaded drain line. Threaded Reducer Elbow 3/4...
  • Page 6: Clearance Specifications

    CLEARANCE SPECIFICATIONS (See Note 2) J or K = FIREPLACE OPENING = AIR SUPPLY INLET = AREA WHERE FIREPLACE IS NOT PERMITTED 2 in..clearances above grade, 3 ft. (USA) ..clearance to service regulator veranda, porch, deck or 6 ft.
  • Page 7: Fireplace Installation

    FIREPLACE INSTALLATION Step 2. Level the firebox by checking the top ROUTING GAS LINE edge of the firebox. Shim if necessary. Step 1. Frame these appliances as illustrated in Route a 1/2" (13 mm) gas line along the inside Step 3. The fireplace should be secured to the Figures 7 through 9.
  • Page 8: Fireplace Specifications

    FIREPLACE SPECIFICATIONS Dimensions - Inches (millimeters) Dimensions - Inches (millimeters) Model No. Model 41-3/4 23-1/2 41-3/4 23-1/2 36” Model (940) (1061) (597) VRE4336 (1061) (597) (940) 47-3/4 29-1/2 42” Model (1092) 47-3/4 (1213) 29-1/2 (749) VRE4342 (1213) (749) (1092) (508) Weight And Volume Model Model...
  • Page 9: Framing Specifications

    FRAMING SPECIFICATIONS Back Wall Of Corner Installation Chase/Enclosure Opening VRE4336 VRE4342 Including Finishing 42-3/4" (1086) 48-3/4" (1238) Materials If Any 46-1/2" (1181) 46-1/2" (1181) 23-9/16" (599) 29-9/16" (751) 11-1/4" (286) 14-1/4" (362) 63-1/2" (1613) 69-1/2" (1765) 31-3/4" (807) 34-3/4" (883) 20-1/2"( 521) 20-1/2"( 521) 44-3/16"...
  • Page 10: Field Wiring

    FIELD WIRING PILOT BURNER ELECTRONIC IGNITION WIRING DIAGRAM IGNITER-SENSOR ASSEMBLY NOTES: CAUTION: Label all wires prior to disconnec- 1. If any of the original wire as supplied must be replaced, use Type AWM 105°C - 18 gage wire ONLY. IGNITER FLAME 2.
  • Page 11: Connecting Gas Line

    CONNECTING GAS LINE Gas Flex Line Connector Codes require a shut-off valve mounted in the 3/8" NPT x 3/8" 1/2" x 3/8" Flare supply line. Figure 12 illustrates two methods Shut-Off Valve Flare Fitting Valve for connecting the gas supply. The flex-line method is acceptable in the U.S., however, Canadian requirements vary depending on 3/8"...
  • Page 12: Installing The Logs

    WARNING Rear Log DO NOT OPERATE THE FIREPLACE FOR ANY EXTENDED PERIOD OF TIME WITHOUT THE VOLCANIC STONE IN PLACE. THE PAN CAN OVER HEAT AND MAY WARP AND THE FIREPLACE MAY SHUT OFF AUTOMATICALLY. INSTALLING THE LOGS After verifying that the fireplace operates properly, replace the cover and set the bottom refractory components in place.
  • Page 13: Checking Appliance Operation

    CHECKING APPLIANCE OPERATION Carbon Monoxide Poisoning: Early signs Only noncombustible materials like marble, of carbon monoxide poisoning are similar stone, tile, brick, etc. may overlap the top With gas line installed run initial system check- to the flu with headaches, dizziness and/ and sides of the front facing.
  • Page 14: Accessories And Components

    INSTALLATION ACCESSORIES AND COMPONENTS Drain Pan The drain pan is used with the appliance. Drain Pan Drain Pan Cat. No. Model Description Cat. No. Model Description H4651 DPSS36 Drain Pan (36) H4651 DPSS36 Drain Pan (36) H4652 DPSS42 Drain Pan (42) H4652 DPSS42 Drain Pan (42)
  • Page 15: Gas Conversion Kits

    GAS CONVERSION KITS Remove Tube Remove Clip WARNING This conversion kit shall be installed by a qualified service agency in Shutter Opening accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruction is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life.
  • Page 16 Step 6. (Refer to Figure 19 on page 15 ) Pressure-Tap Pilot Stage Pilot Gas Terminal (Inlet) Outlet A. Remove the orifice from the manifold with a 1/2" deep throat socket. See the following table for orifice sizes for natural and propane models.

This manual is also suitable for:

Vre4342zenVre4336zepVre4342zep