RM65000
Series
ENGLISH......................................3
FRANÇAIS.................................11
ESPAÑOL...................................19

Advertisement

Table of Contents
loading

Summary of Contents for Broan Rangemaster RM65000 series

  • Page 1 RM65000 Series ENGLISH........3 FRANÇAIS.........11 ESPAÑOL........19...
  • Page 2: To Reduce The Risk Of A Range Top Grease Fire

    READ AND SAVE THESE INSTRUCTIONS WARNING WARNING SUITABLE FOR USE IN HOUSEHOLD TO REDUCE THE RISK OF INJURY TO PER- COOKING AREA. SONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:* TO REDUCE THE RISK OF FIRE, ELECTRICAL 1.
  • Page 3: Prepare The Hood

    PREPARE THE HOOD Unpack hood and check contents. You should receive: 1 - Hood 1 - Decorative Flue Assembly 1 - Parts Bag containing: 2 - Mounting Brackets 1 - Flue Mounting Bracket 10 - Mounting Screws (4,8 x 38mm Pan Head) 2 - Mounting Screws (3,9 x 9,5mm Pan Head) 10 - Drywall Anchors 1 - Installation Instructions...
  • Page 4: Install The Ductwork

    INSTALL THE DUCTWORK ROOF CAP NOTE: To reduce the risk of fire, use only ROUND metal ductwork. DUCT 1. Decide where the ductwork will run between the hood and the outside. 2. A straight, short duct run will allow the hood to perform most efficiently.
  • Page 5: Install The Hood

    INSTALL THE HOOD RECTANGULAR CUTOUTS 1. Hang the hood from the brackets through MOUNTING the rectangular cut-outs on the back of BRACKETS the hood. Cut-outs are larger than the brackets to allow for horizontal adjustment. The bottom of the hood should be 24" to 30"...
  • Page 6: Connect Ductwork

    CONNECT DUCTWORK FLUE MOUNTING BRACKET 1. Use screws and drywall anchors (supplied) to secure flue mounting bracket to the ceiling and wall as shown. 2. Use 6" round metal duct to connect the discharge collar on the hood to the ductwork above.
  • Page 7: Maintenance

    MAINTENANCE Proper maintenance of the Range Hood will assure proper performance of the unit. Grease Filters The grease filters should be cleaned after every 30 hours of operation. This range hood has an operation timer which will alert you after every 30 hours of use by lighting a red GREASE FILTERS LED above the “blower speed 0-1 button”.
  • Page 8: Operation

    OPERATION BLOWER SPEED 4 Controls BLOWER The hood is operated using the (5) push-but- SPEED 3 tons located on the right side of the hood. The light switch turns the halogen lights on BLOWER SPEED 2 and off. Push the light switch once to turn the lights ON - push a second time to turn the BLOWER lights ON to a brighter level - push a third time...
  • Page 9: Fuse Replacement

    RANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone LLC will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
  • Page 10: Service Parts

    SERVICE PARTS MODEL K274 KEY NO. PART NO. DESCRIPTION B02000191 Filter Spring B08087298 Grease Filter B02300233 Motor Capacitor B08091202 Electrical Box Support B03295005 Terminal Cover B02300668 Halogen Lamp Bulb B03292357 Control Board Box B03294033 Control Board Cover B03295002 Ductfree Filter Bracket B02310185 Motor B03295071...
  • Page 11 SERVICE PARTS - LISTE PIECES DE RECHANGE - LISTA DE PIEZAS DE RECAMBIO MODEL K274...