Voltage of Connectors according to Indoor Fan Speed
INDOOR
FAN
MOTOR
CN-DC/DC
1 2 3 4 5
BL BK BR RD
INDOOR PWB ASSY
Indoor
Connecting Terminal
No. of pins
+
-
4
3
INDOOR
CN-
MOTOR
2
3
4
2
INDOOR
CN-
DC/DC
3
2
4
2
OUTDOO
R CN-
DC/DC
3
2
Input Power
1
TAB-N
Connecting wires
between Indoor
and Outdoor
Outdoor
Connecting Terminal
12k
DC Voltage( 10%)
S-Hi
Hi
Med
35.5
32.96
25.17
17.28
11.97
11.97
11.97
11.97
35.5
32.96
25.17
17.28
15.87
15.87
15.87
15.87
35.5
32.96
25.17
17.28
15.87
15.87
15.87
15.87
Troubleshooting Guide
3
4
3
RY-COMP-A
RY-COMP-B
CN-DC/DC
BL
1
BK
2
BR
3
RD
4
Low
Off
0
11.97
0
15.87
0
15.87