Page 1
Viking Installation Guide Viking Range Corporation 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-VIKING1 (845-4641) or visit the Viking Web site at vikingrange.com Designer Hoods F20472 (062207J)
Dimensions ___________________________________________________________________ 24 single speed ventilator. All Viking ventilator kits are Electric Shock, Install this rangehood only with designed specifically for use with Viking hoods. Use of any remote blower models manufactured by Viking, Clearance Dimensions ____________________________________________________________ 25 model numbers – DEV900/DEV1200, non-Viking ventilator kit will void the hood warranty.
Dimensions & Specifications IMPORTANT– Please Read and Follow! (DCH 12”H. Classic Chimney Wall Hoods w/Standard Ventilator) W A R N I N G ” ( 4 0 TO REDUCE THE RISK OF INJURY TO PERSONS ” ( 3 0 IN THE EVENT OF A RANGETOP GREASE FIRE, OBSERVE THE FOLLOWING.
Installation (DCH 12”H. Classic Chimney Wall Hoods w/Standard Ventilator) Planning Information Plan where the duct work will be located. Install 300 or 600 CFM proper-sized duct work, roof, or wall cap for the Roof cap single blower interior-power type of blower you are using. Adjust your 7”...
Slide filter front over front lip. Push filter rear up, then CAUTION: If not using a duct cover, using screws CAUTION: Secure vent hood to wall using screws slide back over rear lip. provided. Use additional mounting screws and wall provided make sure top mounting screws are secured anchors, if necessary.
Installation (DCH 12”H. Classic Chimney Wall Hoods w/Recirculating Kit) Remove damper and discard with transition. Turn recirculating unit upside down. Place vent hood Flip hood over. Insert 6” of electrical wiring through the CAUTION: Secure vent hood. Make sure mounting upside down on recirculating unit.
To install ventillation kit refer to ventillation kit installation instructions. Slide spacer front over front lip. Push spacer rear up, Slide filter front over front lip. Push filter rear up, then Slide filter front over front lip. Push filter rear up, then then slide back over rear lip.
Page 19
Place duct cover top inside duct cover base and lower until Slide duct cover in place and fasten from inside canopy Insert 6” of electrical wiring through the top of vent hood CAUTION: Using screws provided secure vent hood to wall. desired height is found.
Slide filter front over front lip. Push filter rear up, then Slide spacer front over front lip. Push spacer rear up, Place duct cover top inside duct cover base and lower until Slide duct cover in place and fasten from inside canopy slide back over rear lip.
Installation (DCIH Classic Chimney Island Hoods) Run duct work down to bottom edge of duct Attach canopy to duct cover/soffit. From inside of Check framing where cutout will be. Cut appropriate size hole in ceiling. Either 7” or 10” cover/soffit and secure in place. Make sure the duct hood, seal top of hood to duct with aluminum tape.
Wiring Diagram Service & Registration Service & Parts Only authorized replacement parts may be used in performing service on the appliance. Refer only to features equipped with this unit Do not repair or replace any part of the appliance unless specifically recommended in the manual.