Safety; Electrolytic Capacitors; Main Parts Check; Temperature Sensor Checking - Kaisai KFU-09HRDN1-QRC8W Service Manual

Kaisai 12f inverter series split type air conditioners
Table of Contents

Advertisement

Safety

Electricity power is still kept in capacitors even the power supply is shut off. Do not forget to discharge the
electricity power in capacitor.

Electrolytic Capacitors

(HIGH VOLTAGE! CAUTION!)
Connect discharge resistance (approx.100Ω 40W) or soldering iron (plug) between +, - terminals of the
electrolytic capacitor on the contrary side of the outdoor PCB.
Note: The picture above is only for reference. The plug of your side may be different.

Main parts check

1.

Temperature sensor checking

Disconnect the temperature sensor from PCB, measure the resistance value with a tester.
65